HomeMy WebLinkAbout302298_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101115140
PROJECT ADDRESS:
2069 S Garnsey St Unit# 2
PLAN CHECK ENGINEER:
Lo, JonathanTEL:714
647-5822
EMAIL:
Jlo@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
5/18/2023
INITIAL REVIEW
5/31/2023
EXPIRATION
11/14/2023
RECHECKS:
1.6/26/2023
PROJECT APPLICANT CONTACT PERSON:
2.
Brenda Gutierrez
3.
TEL:
(714)306-5409
FAX:
VALUATION:
EMAIL:
brenda.e.gutierrez@gmail.com
FLOOD ZONE: X-0602320276J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment.Comments have been provided on drawing and calculation hard copies in relation to all comments below. Applicant must pick up red marked sets from city prior to resubmittal and return marked up set with resubmittal.DocumentationVerify if revisions occur on all sheets provided in revision set. Submitted Revision Set should have revised sheets only or complete set with all original sheets. DrawingsSheet S1.0Fix Holdown notes specified on plans. All holdown notes look misaligned.Specify new foundation on foundation plan where occurs. Note still specifies existing foundation.Provide new foundation embed depth below lowest adjacent grade. Detail references plans.Specify new slab on grade on plan where occurs, note still specifies existing. Provide new slab on grade foundation information on plan.PC #2: Slab on grade foundation not found on drawings. Please provide.Verify if detail 1/S1.0 and 2/S1.0 still applies to project. Remove if not applicable. (End of Comment)