HomeMy WebLinkAbout300483_3_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101114531 PROJECT ADDRESS: 1013 W Alton Ave PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 4/4/2023 INITIAL REVIEW 5/17/2023 EXPIRATION 10/1/2023 RECHECKS: 1.7/10/2023 PROJECT APPLICANT CONTACT PERSON: 2.7/24/2023 Khan Bui 3. TEL: (714)272-7427 FAX: VALUATION: $11,000.00 EMAIL: kt.design.ca@gmail.com FLOOD ZONE: X-0602320259J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment.The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2022California Building Standards Code with local amendments and to clearly indicate the scope of work under this building permit application. There may be additional requirements when complete construction drawings and supporting data is submitted for Building Safety Division review. 6. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance(CHECKED BOXES REQUIRED ONLY): ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☒Public Works Agency approval (647-5039). ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. Applicant must pick up red marked sets from city prior to resubmittal and return marked up set with resubmittal.DocumentationTitle 24 shall be updated to 2022 code.Provide a complete floor plan of new floor. Floor Plan shall include the following:Show Room Labels & Room DimensionsShow Bathroom FixturesShow smoke alarms and carbon monoxide alarmsShow ceiling heights in each roomAll new walls and window infill shall be specified on plans via hatch with Wall Legend.Show new kitchen layout and where major appliances occur. Specify existing kitchen hood, hood to be 100 CFM MIN.Provide details for top and bottom connection of new interior non-bearing walls.PC #2: Provide smoke detector directly outside vicinity of new bedroom. PC #3: Comment should have stated carbon monoxide alarm, please provide carbon monoxide alarm outside vicinity of new bedroom. DrawingsSheet A00XRevise Occupancy Type to R-3/U, else verify R-1.Specify if existing structure is Sprinklered or not in Building Data.Provide 2022 Code references on cover sheet.Revise plan title to Current “Unpermitted” Floor/Site PlanAdditional CommentsSheet A00XNotes and detail references on plans are not legible. Please enlarge or provide enlarged plan as needed. SKYLIGHTSSpecify manufacturer's name and ICC approval number for skylights. (CRC R308.6.9)PC #3: Manufacturer and ICBO number provided in detail does not match Report provided. Revise as needed or provide new report. Ensure product report is compliant with current 2022 CBC.Specify glazing material shall be fully tempered, heat-strengthened, wired, approved rigid plastic, or laminated in accordance with CRC R308.6.2. Screens shall be provided to glazing that is not fully tempered meeting the requirements listed in R308.6.5. (CRC R308.6.3 & R308.6.5) Provide skylight details to show flashing and 4-inch minimum mounting height. (CRC 308.6.8) Submit calculations, specifications, and construction details for skylights that are not third party approved. (End of Comment)