HomeMy WebLinkAbout300879_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
102114657
PROJECT ADDRESS:
1025 S Driftwood Dr
PLAN CHECK ENGINEER:
Lo, JonathanTEL:714
647-5822
EMAIL:
Jlo@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
4/13/2023
INITIAL REVIEW
5/30/2023
EXPIRATION
10/10/2023
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Leon Tran
3.
TEL:
(714)418-6604
FAX:
VALUATION: $40,000.00
EMAIL:
trandesign7@gmail.com
FLOOD ZONE: X-0602320256J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment.
5. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance(CHECKED BOXES REQUIRED ONLY):
☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process.
☒Public Works Agency approval (647-5039).
☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700).
☐Police Department approval on the corrected/final set of drawings (647-5840).
☒School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work.
☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. Applicant must pick up red marked sets from city prior to resubmittal and return marked up set with resubmittal.DrawingsSheet A1SEOR stamp shall be updated and signed prior to approval.Revise (E) Patio cover = 240 SF to (N).Add new 240 SF lattice patio cover to scope of work.Update code references on all sheets to 2022 codes.Add sheet A2.1 to Sheet Index.Sheets CG1 and CG2 have not been provided, please provide sheets.Verify Photovoltaic System note applies to application. If not, remove note.Provide drawings and calculations for new 240SF lattice patio cover.Provide drainage and flow direction around new addition and throughout plot on plan.Sheet A2Provide dimensions for new bedroom to locate all walls.Sheet A3Provide proposed roof system and ICC #. Sheet A4Verify North arrow direction with Sheet A1. North arrows do not match.Verify Note 2 referenced at underpinned foundation. Note does not seem to match reference.Add holdowns @ all Shearwall ends, else provide lateral calculations justifying no holdowns.Provide reinforcing for patio post foundation. Sheet A5Add shearwall along wall between (N) Family Room and Garage, else provide lateral calculations for proposed lateral design layout.(End of Comment)