Loading...
HomeMy WebLinkAbout297944_3_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 102113709 PROJECT ADDRESS: 1810 S Broadway Unit# 4 PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 2/1/2023 INITIAL REVIEW 3/21/2023 EXPIRATION 7/31/2023 RECHECKS: 1.7/17/2023 PROJECT APPLICANT CONTACT PERSON: 2. Jessica Arias 3. TEL: (951)373-7707 FAX: VALUATION: $44,000.00 EMAIL: jessica@empireresurfacinginc.com FLOOD ZONE: X-0602320276J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment. 5. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance (CHECKED BOXES REQUIRED ONLY): ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☐Public Works Agency approval (647-5039). ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. Applicant must pick up red marked sets from city prior to resubmittal and return marked up set with resubmittal.DrawingsSheet 1Provide Sheet Label.EOR stamp is not legible. Restamp and ensure not expired for current submittal. Provide a complete plot plan showing – (R106.2) ☒Location and size of all structures on the lot. ☒Identify all property lines and easements, streets, etc. ☒Show north arrow. ☒Distances between buildings (main house, detached garage, accessory dwelling unit, etc.). ☒Distances (setbacks) between buildings and property lines.Provide Occupancy Category in Project Data.PC #3: Comment not addressed, Occupancy Category: R-2 should be provided in Project Data. Sheet Index does not match sheets provided. Ensure all sheets are adequately labeled and revised sheet index.Sheet A-1EOR stamp is not legible. Restamp and ensure not expired for current submittal. If details on sheet A-1 is similar to enlarged details provided, remove sheet A-1 or enlarged detail sheets and cover page. There should not be repeated details in submitted drawing set. NOTE: All comments on enlarged detail sheets apply to details on Sheet A-1 if this is sheet is to be kept.Sheet 3Remove Structural Details for Damaged Wood report from drawing set and provide in separate package. Else remove Sheet A-1 and label each enlarged detail sheet adequately.PC #2: Please verify if report has been provided, please provide engineer report on 8 ½”x11” size.Sheet P-1Provide Sheet LabelSheet to be stamped and signed by EOR.Site Plan specifying area of work is not legible. Revise to make area of work callout and circled on plan more legible. Sheet P-2Provide Sheet Label.Sheet to be stamped and signed by EOR.Provide new material grades and notes as needed for replaced/new items. (e.g. Wood Grade).Provide connection from existing holdown to new 4x10 post. Sheet P-3Provide Sheet Label.Sheet to be stamped and signed by EOR.Provide new guardrail member sizes including horizontal member and new posts.Provide new guardrail post spacing on section.Provide Calculations for guardrail replacement including post member and base connection.Specify existing sheathing information to be replaced or specify like for like replacement. It should be noted to verified in field to ensure new is equal or better. Else calculations will be required for shearwall replacement.Sheet P-4Provide Sheet Label.Sheet to be stamped and signed by EOR.Provide spacing for new sill anchors in epoxy. Sheet Findings ReportRemove findings report from submitted drawing set and provide as separate package. Report recommendations note that weak connections should be designed by the registered licensed engineer. Please specify what connections are intended to be redesigned and provide calculations. Additional CommentsProject Name/Address and Firm Name/Address is not legible on cover sheet. Please reprint with legible information.Original drawing sheet P-3 is not provided in resubmittal, but noted to see revised. Please provide sheet P-3. (End of Comment)