Loading...
HomeMy WebLinkAbout307505_1_Corrections.docxSPC PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101116694 PROJECT ADDRESS: 1995 S Standard Ave PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B, SPK OCCUPANCY CLASSIFICATION(S): B, H-3, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 9/19/2023 INITIAL REVIEW 10/3/2023 EXPIRATION 3/17/2024 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Javier Cambero 3. TEL: (909)237-2219 FAX: VALUATION:$25,000.00 EMAIL: javier.cambero@nhmh.com FLOOD ZONE:X-0602320276J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please refer to red marks on the drawings for additional plan check comments. Revise drawings to show compliance.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714) 573-6100).Sheet T1-0. Show correct type of construction: III-B.Sheet T1-0. Show occupancy group: B, H-3, F-1.Sheet T1-0. Specify the content/material to be stored on the racks.Sheet T1-0. Update the number of the total racks and indicate type of racks in the scope of work. By calculating the drawings, the revised plan shows (10) type A racks and (4) type B racks. Please clarify and show correct number and type of racks in the scope of work. The modification, removing existing or adding new fences and gates are not part of this permit scope. Please complete remove any proposed work of them from the drawings.Indicate the total height of rack including the material height show on top shelve per allowable height specified in structural calculations. Show also provided vertical clearance between bottom of the roof/ceiling and top of the stored material on the top racks.Sheet A2-0. Draw and print the egress plan to scale.Sheet A2-0. Show occupancy group and square footage of the storage area where the proposed racks are located.Add following note on plan: Table 1017.1 Exit Access Travel Distance: OCCUPANCYWITHOUT SPRINKLERWITH SPRINKLERSYSTEM (feet)SYSTEM (feet) S-1200250 B200300 H-3Not Permitted150Sheet A2-0. Revise the travel distance calculation from the remotest point by the existing fence at the end of the aisle between rack A and rack B to an exit. Justify the travel distance.Sheet A2-0. Two exits or exit access doorways from any space shall be provided where the design occupant load or the common path of travel distance exceeding the values listed in Table 1006.2.1. Recommend to remove (2) proposed type A racks to provide second exit. See red mark on plan.Sheet A2-0. Add note to plan: “The egress route is not allowed to go through underside of the racks or equipment platform”.Steel storage racks and their anchorage, where the importance factor is equal to 1.5 inaccordance with Section 15.5.3 of ASCE 7.Lower portions of posts exposed to damage by forklift trucks or other moving equipment shall have protective devices. If not so protected, at the option of the building official, the rack structure may: (1) be designed to maintain its full design load capacity at allowable stresses with the exposed post capacity reduced by one-half or (2) be designed to maintain its full design load capacity at 50 percent increased allowable stresses with the exposed post assumed to have no carrying capacity.In the structural calculation book, please include all pages of calculation for rack type B.Load application and rack configuration drawings shall be furnished with each rack installation. The drawings shall present the permissible configurations or limitations as to the maximum number of shelves or rails, the maximum distance between them, and the maximum distance from the floor to the bottom shelf or rail.In the structural calculation book, please include all pages of calculation for rack type A and type B (single and back-to-back).Sheet SED. Provide longitudinal and traverse elevation for rack type B. Clearly label each elevation on sheet SED.END OF COMMENTS