HomeMy WebLinkAbout304947_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101115966 PROJECT ADDRESS: 2529 S Diamond St PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/27/2023 INITIAL REVIEW 8/24/2023 EXPIRATION 1/23/2024 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Anh Phan 3. TEL: (714)487-7926 FAX: VALUATION: $55,000.00 EMAIL: anhtuanxd04@gmail.com FLOOD ZONE: X-0602320259J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.All persons preparing plans for others shall sign those plans. Business and Professions Code Chapter 3, Division 3, Section 5536.1 (a). This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Public Works Agency approval (647-5039). - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. Sheet A1. Please revise the number of stories of the building to two. Sheet A1.1. Please show and indicate north arrow on both site plans. Sheet A3. The existing 3056 CS window next to the new 5068 door must meet the safety glazing provisions per R308.4.2. Please show compliance on plan. Code: Glazing within 24” arc of either vertical edge of the door and less than 5’ from the walking surface shall be safety glazed. (CRC R308.4 (2)) Sheet N1 does not have complete CALGreen requirements. Incorporate 2022 CALGreen residential mandatory requirements on the drawings. The complete checklist with requirements can be found on AIA website: https://aiacalifornia.org/learn-grow-practice/practices/calgreen-checklists/ . Please incorporate AIA’s checklist (2 sheets) and indicate each applicable mandatory requirement by selecting Y in the checkbox that applies to this project. Sheet T24.1. Please include the new 6040 window (bedroom #3) and the new 5068 (family room) glazing door into energy design. Sheet S0. General note #1. Please revise the compliance code from California Residential Code to California Building Code. END OF COMMENTS