Loading...
HomeMy WebLinkAbout300388_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101114495 PROJECT ADDRESS: 1618 W First St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 4/3/2023 INITIAL REVIEW 4/9/2023 EXPIRATION 9/30/2023 RECHECKS: 1.10/7/23 PROJECT APPLICANT CONTACT PERSON: 2. JovenLactaoen 3. TEL: (323)304-3275 FAX: VALUATION: $60,000.00 EMAIL: Jovensinc@gmail.com FLOOD ZONE: X-0602320257J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Sheet A2: On the plan, please provide an accessible route from the public sidewalk to the primary accessible entrance. Accessible route shall be 5% slope maximum, measured in the direction of travel, and 2% maximum cross-slope. 2nd Review Comment: Accessible route from the public sidewalk was not provided. Please provide an accessible route from the public sidewalk (on First Street) to the building accessible entrance. Accessible route shall be 5% slope maximum, measured in the direction of travel, and 2% maximum cross-slope.Accessible path of travel that exceeding 5% slope shall be designed as ramp in accordance with Section 11B-405.Accessible path of travel that exceeding 5% slope shall be designed as ramp in accordance with Section 11B-405. 2nd Review Comment: Please comply with Section 11B-405 for accessible ramp, if a ramp is required.Sheet A3: 2nd Review Comment: Sign Pole Detail: Please revise detail to show the 80” clear measured to the bottom of the lowest sign. Details: Please provide correct Letter callout for each details provided. Details shall be clearly cross-referenced onto the plan at where it occurs. Delete/omit detail that does not apply to the project. Sheet A4 & A5: If there are multiple tenant spaces (suites), please clearly identify/label demising walls and suite number on the plan. 2nd Review Comment: New furred-out wall adjacent to the existing stairway (Detail A/A5) – Please provide fire-blocking at every 10-ft horizontally in the concealed wall space. Accessible toilet compartments – please show dimension of 60” clear compartment and water closet located at 17”-18” from the adjacent wall. 2nd Review Comment: on the plan, please clearly reference to sheet A6 for accessible restroom information. Sheet A6: 2nd Review Comment: Please clearly cross-reference all information onto the floor plan so that it can be easily located. (End of Comment)