HomeMy WebLinkAbout308381_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101117027-28
PROJECT ADDRESS:
5015 W Edinger Ave Unit# M
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B, SPK
OCCUPANCY CLASSIFICATION(S):
B, M
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
10/9/2023
INITIAL REVIEW
11/8/2023
EXPIRATION
4/6/2024
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Miguel Flores
3.
TEL:
(562)512-0686
FAX:
VALUATION: $8,500.00
EMAIL:
miguel.fl@westlandreg.com
FLOOD ZONE: X-0602320256J
APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)An application for a permit for any proposed work shall be deemed to have abandoned / expired after 180 days of the date of filing, unless such application has been issued.Sheet CS.1: The proposed wall is not a “truth” one-hour fire-rated wall – Please revise scope of work item #1 just stating installation of a new demising wall. Sheet SA100: Some of the locations the existing truncated domes were installed in the incorrect location. Please revise detail 2, 3, and 4 to remove the truncated domes that installed in the access aisle, in the parking lot. Detail 4: remove and provide new truncated dome at the pedestrian ramp landing (before it crosses the parking area). Sheet A100, Unit N: Provide detail for stairway leading to the alley, show rise, run, landing and handrails. Stairway at the employee room giving access to the ally – Stair shall comply with chapter 10 for means of egress and Chapter 11B for accessibility. Provide stairway detail, show rise, run, landing and handrails. Restrooms: Restrooms shall be accessible to the persons with disabilities. Please provide enlarged restroom plans with all the required dimensions and fixture details. Sheet A100, Unit M: Provide detail for stairway leading to the alley, show rise, run, landing and handrails.Restroom shall be accessible to the persons with disabilities. Please provide enlarged restroom plan with all the required dimensions and fixture details. Door opens to the breakroom – Please remove/rearrange cabinet/furniture to provide minimum 18” clear from the door strike edge. Sheet A100: Proposed floor plan note 1 – The proposed wall is not a “truth” one-hour wall, please revise note to state “Install New Demising Wall”. On the plan, please show landing and maneuver space for all the exterior doors.
(End of Comment)