HomeMy WebLinkAbout308978_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
104117186
PROJECT ADDRESS:
2140 S Yale St
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
III B, SPK
OCCUPANCY CLASSIFICATION(S):
B, F-1, S-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
10/24/2023
INITIAL REVIEW
11/4/2023
EXPIRATION
4/21/2024
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Carl Ludwig
3.
TEL:
(714)340-5114
FAX:
VALUATION: $50,000.00
EMAIL:
AMERICANDRAFTER@GMAIL.COM
FLOOD ZONE: X-0602320258J
APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceAn application for a permit for any proposed work shall be deemed to have abandoned / expired after 180 days of the date of filing, unless such application has been issued.Any alteration to the existing Automatic Sprinkler shall be submitted Sprinkler plans to the Orange County Fire Authority (OCFA) for review and approval. Sheet A-0.0: Occupancy Groups: Please specify occupancy groups (B, F-1, S-1) for the existing building, permit record. Type of Construction: Please specify construction type (III-B) for the existing, per permit record. Site plan: Please provide/show an accessible route from the public sidewalk to the building primary accessible entrance. Site plan: Please show/provide accessible parking spaces complying with Section 11B-502, and provide an accessible route from the accessible parking stalls to the building entrance. Provide detail and clearly cross-reference details onto the plan. Provide/show detectable warning along the accessible route where’s required. (11B-247)Sheet A-02: Provide/show accessible parking stalls and provide an accessible route to the building entrance. Accessible parking stalls shall be complied with Section 11B-502. Provide details and clearly cross-reference details onto the plan. Sheet A-1.6: Restrooms shall be made accessible to the persons with disabilities, complying with Chapter 11B, Division 6. Please provide enlarge restroom plans showing compliance with Chapter 11B, Division 6. (End of Comment)