HomeMy WebLinkAbout307511_2_Corrections.docxSPC PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101116697 and 101116699 PROJECT ADDRESS: 1029 E Fourth St and 1029 ¾ E Fourth St WCC02 PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 9/18/2023 INITIAL REVIEW 9/28/2023 EXPIRATION 3/16/2024 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Brian De La Ree 3. TEL: (323)273-2199 FAX: VALUATION:$10,000.00 and $40,000.00 EMAIL: bdelaree@core.us.com FLOOD ZONE:X-0602320276J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840). - Public Works Agency approval (647-5039).PLAN CHECK COMMENTSRevise the project address to “1029 E Fourth St and 1029 ¾ E Fourth St WCC02”. Please ensure the correct address is updated throughout the construction document.Sheet A-1. Update the construction type to type V-B.Sheet A-2. Wrought iron enclosure. Where the enclosure wall/fence is less than 10 feet fire separation distance to the lot line (e.g. ±6’-11” to west lot line), revise design to provide 1-hour fire rating exterior wall per Table 705.5 and comply with the opening limitation per Table 705.8. Per submitted enclosure design, revise the enclosure location having at least 10 feet to any lot line or revise the design.Wrought iron enclosure. Provide structural design and detail at the connection where the HSS beam connected to the HSS column on plan.Wrought iron enclosure. Provide structural design and detail of the 1” wrought iron pickets and the connection where connected to the HSS beam on plan.Wrought iron enclosure. Please justify the footing design for HSS columns to support the most critical seismic load combination. CBC 2022, ASCE 7-16.END OF COMMENTS