Loading...
HomeMy WebLinkAbout307270_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101116614 PROJECT ADDRESS: 1404 E St Gertrude Pl PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): F-1, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 9/12/2023 INITIAL REVIEW 9/26/2023 EXPIRATION 3/10/2024 RECHECKS: 1.11/28/23 PROJECT APPLICANT CONTACT PERSON: 2. Mariano Canillas 3. TEL: (714)655-6184 FAX: VALUATION: $636,480.00 EMAIL: mario.greenforest@gmail.com FLOOD ZONE: X-0602320276J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS An application for a permit for any proposed work shall be deemed to have abandoned / expired after 180 days of the date of filing, unless such application has been issued. All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039) - Orange County Sanitation District (714) 593-5756Sheet A3.11: One-hour wall and ceiling assembly as required for the exit passage way – Please provide ICC or UL listing report number for the fire-rated thermal fiber panel; otherwise, provide construction detail for a one-hour fire-rated wall and ceiling assembly. Provide details on plans and provide verification of a tested assembly to achieve the required fire-rating. 2nd Review Comment: New one-hour ceiling assembly above the exit passageway – minimum ½” plywood sheathing is required on top of the steel C ceiling joists. Please provide details to show how the ½” will be installed on the steel ceiling joist, where the existing floor joist is located directly above it; the one-hour wall may need to extended to the underside of the existing floor sheathing. Please provide details and clearly cross-reference details onto the plan. Door D19 open to the exit passage way: Please provide minimum 1-hour rated door with smoke seal. 2nd Review Comment: Door schedule sheet A4.12 was missing. Please provide updated sheet A4.12 with the required information above. PLEASE PROVIDE TWO (2) COMPLETE SETS OF FINAL PLANS FOR FINAL REVIEW AND APPROVAL. (End of Comment)