Loading...
HomeMy WebLinkAbout304507_4_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101115822 PROJECT ADDRESS: 703 S Euclid St Unit# F PLAN CHECK ENGINEER: Ahangian, KathyTEL:714 647-5812 EMAIL: Kahangian@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/14/2023 INITIAL REVIEW 8/23/2023 EXPIRATION 1/10/2024 RECHECKS: 1.9/17/23 PROJECT APPLICANT CONTACT PERSON: 2.10/4/23 Larissa Baesu 3. TEL: (714)944-9688 FAX: VALUATION: $50,000.00 EMAIL: socalpermitrunner@gmail.com FLOOD ZONE: A-0602320256J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceOn floor plan ( sheet A-2) , show living room wall as a new wall per detail 7/ D-1.Ok 9/17/23Per attached pictures , seems like stairways are damaged and needs to be replaced . provide complete structural calculation and construction detail for the stairways, guardrails and handrails.Pending 9/17/23Show width of the stairwayOk10/4/23Handrails are required on at least one side, please show on the floor plan.Ok10/4/23Provide dimension for the top and bottom landing.Ok10/4/23The top of handrails shall be placed not less than 34” and more than 38 inches above the nosing of the tread .a clear space of 1-1/2 inches is required between the handrail and the wall. Please show detail.Ok10/4/23Provide dimensioned details of handrail grips.Ok10/4/23Provide a 42-inch high guardrails.Ok10/4/23Provide framing member and framing details for stairway on the framing plan.See Comment # 15 Show how stairways framing members including all the beams and stringers are supported ( on the framing plan) provide post / beam connection detail.See Comment # 15Show footing from detail 10/D-1 on the foundation plan.See Comment # 15Show stairway positively anchored to the primary structure.See Comment # 15Enclosed usable space under a stairway requires 1 / 2 inch gypsum board on the enclosed side Ok10/4/23Provide calculation for the stringer.See Comment # 15This project is a fire damage repair, trusses cannot be as a deferred submittal. Truss calculation and truss plan shall be provided at the time of plan review. Pending 9/17/23 Provide shear transfer detail for Truss # A1 over to the wall below.Ok 10/4/23 Show length of beam #1 on sheet S-1. Ok 9/17/23On detail 7/ D-1, provide shear transfer detail.Ok 9/17/23Provide 6x post on detail 6/D-1.Ok 9/17/23Please change the project address on the calculation to match the address and the city on the application.Pending 10/4/23 Please change address to reflect “City of Santa Ana”10/4/23Engineer of record shall provide a letter on the letter to note that he visited the site and certify that other structural elements that are not part of this review are sound and intact, and identify the area that need replacement.