Loading...
HomeMy WebLinkAbout309075_3_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101117222 PROJECT ADDRESS: 1851 E First St Unit# 810 PLAN CHECK ENGINEER: Ahangian, KathyTEL:714 647-5812 EMAIL: Kahangian@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: I A, SPK OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/25/2023 INITIAL REVIEW 11/5/2023 EXPIRATION 4/22/2024 RECHECKS: 1.11/25/23 PROJECT APPLICANT CONTACT PERSON: 2. Lizzy Cadwell 3. TEL: (949)724-1499 FAX: VALUATION: $190,000.00 EMAIL: lizzy@spaces-oc.com FLOOD ZONE: X-0602320277J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceProvide number of exits required by CBC Sections 1006. Ok 11/25/23Each unit has to have access to two exits( 2 stairways). CBC 1006.3.4. ( Unit 810 has access to one stairway)Pending 11/25/23 Unit #810, has only access to 1 stairway.CBC Section 1005.7.1. Doors, when fully opened, and handrails shall not reduce the required width by more than 7”. Doors in any position shall not reduce the required width by more than one-half. Other nonstructural projections such as trim and similar decorative features are permitted to project into the required width 1.5” from each side.Ok 11/25/23Complete the attached Disabled Accessibility Documentation Form.Ok 11/25/23Provide floor plan for unit 800.Pending 11/25/23, Since it is an alteration to suite 800, floor plan is required. is it only open floor?Please verify if the ceiling is new or existing.Ok 11/25/23Provide gauge number for bottom track on detail 6/A-5. Pending 11/25/23, Ga 25 is not strong enough for 9’ tall wall, provide min 20 Ga. or provide calculation to justify.Show reach height for the microwave complies with accessibility.Ok 11/25/23