HomeMy WebLinkAbout307913_3_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101116849 PROJECT ADDRESS: 1431 S Orange Ave PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 9/27/2023 INITIAL REVIEW 11/3/2023 EXPIRATION 3/25/2024 RECHECKS: 1.12/19/23 PROJECT APPLICANT CONTACT PERSON: 2. Silvia Flores 3. TEL: (714)914-1081 FAX: VALUATION: $25,000.00 EMAIL: silviachapis@sbcglobal.net FLOOD ZONE: X-0602320276J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. Sheet S1: Please provide the following Helical anchors and piers: Please revise detail to be legible, and provide details for raised-floor foundation condition. On the plan, please provide ICC / UL listing number for the preapproved foundation reinforced/repair system (helical piers and anchors). 2nd Review Comment: the helical piers system shall have a listing number by ICC or UL. On the plan, please provide ICC / UL listing number of the helical piers and its specification. On the plan, please provide procedures for the proposed foundation repair/improvement. Sheet 1: Please submit foundation plans to the geotechnical engineer of record for review and approval. The foundation plan shall be “reviewed” stamped by the geotechnical engineer of record for general conformance with the geotechnical engineer’s recommendation. Soil report: Please revise/provide soil report recommendations for the existing raised floor foundation, which reflects to the existing building condition, and the proposed Helical piers and anchors. (End of Comments)