HomeMy WebLinkAbout311810_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101118038 PROJECT ADDRESS: 910 S Susan St PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/22/2024 INITIAL REVIEW 1/28/2024 EXPIRATION 7/20/2024 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Byron Do 3. TEL: (714)856-5704 FAX: VALUATION: $103,700.00 EMAIL: bydezygn@yahoo.com FLOOD ZONE: X-0602320256J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance (CHECKED BOXES REQUIRED ONLY): ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☒Public Works Agency approval (647-5039). ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☒School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. Applicant must pick up red marked sets from city prior to resubmittal and return marked up set with resubmittal.DrawingsSheet A1.0 Provide the following design data on the first sheet (R106.1.1) ☐Sheet Index ☐Occupancy groups (R-3/U) ☐Type of construction (V-B) ☐Automatic Fire Sprinkler (YES or NO) ☒Number of stories. ☒Flood Zone: X ☐Flood Zone: A ☐Flood Zone: AE ☐Floor area per occupancy group, including the existing structure(s) ☐Construction shall comply with the 2022 CRC, CBC, CPC, CMC, CEC, California Green Building Code, and California Energy Efficiency Standards Code editions.Add Sheet S-2 to Sheet Index.Show drainage slope and direction around all sides of new addition on Site Plan. Ensure adequate drainage provided.Sheet A2.0All code references on sheet shall be updated to current codes. City references shall be revised to Santa Ana. No references to other jurisdictions should be noted.Sheet A3.0Existing Floor Plan shows new kitchen island. This shall be provided on New Floor Plan.Verify if new ceiling to occur at new addition. Provide ceiling height. Coordinate with structural as no ceiling joists are noted. Sheet A5.0Show proposed new attic ventilation locations in elevations.Verify new tile and stucco at garage as well as new garage door. Add all intended work to Scope of Work. Detail corrosion–resistant weep screed minimum of 4” above the earth or 2” above paved areas. (R703.7.2.1)Sheet S-2Coordinate garage door location with Architectural. Opening looks to be centered in garage wall. Verify SW length designed.Calculations specify SW Type 2 for Shearwalls along Grid 1 and 2. Please coordinate with calculations and revise as needed.Verify if new ceiling joist to occur at new addition, no ceiling joist sizes provided. Coordinate with Architectural. (End of Comment)