Loading...
HomeMy WebLinkAbout310277_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101117568 PROJECT ADDRESS: 3325 S Harbor Blvd PLAN CHECK ENGINEER: Ahangian, KathyTEL:714 647-5812 EMAIL: Kahangian@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: N/A OCCUPANCY CLASSIFICATION(S): N/A PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/29/2023 INITIAL REVIEW 1/3/2024 EXPIRATION 5/27/2024 RECHECKS: 1.1/29/24 PROJECT APPLICANT CONTACT PERSON: 2. Patrick Faranal 3. TEL: (909)287-7375 FAX: VALUATION: $70,000.00 EMAIL: pfaranal@nsmc.com FLOOD ZONE: X-0602320258J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Pending 1/29/24, drawings shall be legible.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.CBC Sections A106.1 and A106.3.4.1, All drawings and supporting documents shall be prepared, stamped and signed by a California licensed architect or registered civil engineer.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceProvide site plan and show property lines on the site plan. Show location of the canopies on the site plan and show fire separation to the property lines.Footing for the canopies seems shallow; please provide complete non-constraint calculation to justify.Pending 1/29/24, please see comment #10.Please clarify why A is equal to 0.42, versus A=3.11.Pending 1/29/24, Loading (208 psf) seems too low, please include canopy area and the pole area in the loading.