Loading...
HomeMy WebLinkAbout304834_4_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 102115929 PROJECT ADDRESS: 1209 S Parton St PLAN CHECK ENGINEER: Huang, GaryTEL:714 647-5862 EMAIL: Ghuang@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/25/2023 INITIAL REVIEW 8/25/2023 EXPIRATION 1/21/2024 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Dan Cojocnean 3. TEL: (714)669-3870 FAX: VALUATION: $3,000.00 EMAIL: muscatoto@yahoo.com FLOOD ZONE: X-0602320276J GUIDELINES: Comments contained within this report reflect only those of the Building and Safety Division. Additional comments or corrective action may be required by other Departments and/or outside Agencies This Plan Review Report and all subsequent code references are based upon the most recent version(s) of the 2022 California Building Codes (CBC, CRC, CFC, CEC, CPC, CMC, CGBSC, and CEES) The approval of plans and any supporting documents does not permit the violation of any section of the adopted building codes or other pertinent local ordinances, or state and federal laws All listed plan review comments must be adequately addressed before a building permit can be issued Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used. PLAN REVIEW COMMENTS: Applicant shall address all the checked‘☒’ correction comments below before resubmitting plans to Building Safety for recheck. ☒1. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☐Public Works Agency approval (647-5039). ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).☒Additional Review Comment: Sheet A1 Project Data: provide window schedule and indicate which window(s) are change on plan [Comment Resolved] Sheet A2 Roof Plan: provide detail/reference at (N) porch roof to (E) roof cricket [Comment Resolved] Floor Plan: Architect/SEOR to verify reference detail(s). Typical to all details [Comment Resolved] Sheet A4 Framing – Cover patio Provide lateral analysis of the cover patio and illustrate how lateral force is being transfer. Further review is required [ Correct reference 1/A201. [Comment Resolved] Provide beam size supporting the king post at/above the (E) garage [Comment Resolved] Porch Framing Provide ceiling joist size and spacing per detail D10/A5. Provide structural calculation justification [Comment Resolved] Section – Cover patio Verify detail reference D6/A5, should it be D11/A5 [Comment Resolved] Sheet A5 Detail D4: provide/indicate epoxy rebar depth within the (N) slab [Please indicate the concrete cover for cast-in-placed reinforcing] Detail D6: provide detail for how roof rafter to top plate connector [Comment Resolved] Detail D7: provide strap for continuity at roof ridge beam [Comment Resolved] Detail D8: provide roof rafter to beam connector [Comment Not Resolve – provide shear transfer from roof rafter to beam/top plate] Detail D10: provide ceiling joist design [Comment Resolved] Detail D11: provide roof rafter to beam connector [Comment Not Resolve – provide shear transfer from roof rafter to beam] Prior to submit the hard-copy drawings for approval and permit issuance. It is at applicant’s discretion, as an option, to submit a full-set electronic drawing (in pdf format) for a courtesy review. Please include the original red-marked comment drawing set, red-marked calculation, and all supporting document (revised calculation, etc.) for an expedite review. Red marked comment set is available to pick-up at the City Hall.☒Additional Review Comment (9/26/2023): Sheet A4 Cover Patio Provide diaphragm nailing pattern and plywood thickness 4x10 ridge beam (calculation page 16) shall include wind load reaction from roof rafter design 4x6 roof rafter (calculation page 18) shall include wind load (downward and upward) in load combination (15.97 psf and -48.6 psf wind load per calc page 20) Per calculation 33, it is understanding that 6x8 member will take lateral load from elbow. Provide calculation justify 6x8 is adequate to take combined axial load and bending from gravity and lateral. Consider wind loads into load combination Porch Framing Provide diaphragm nailing pattern and plywood thickness Provide calculation for the 2x8 roof rafter design including wind load (upward and downward) in load combination (End of Comment)