Loading...
HomeMy WebLinkAbout308309_3_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101117009 PROJECT ADDRESS: 401 N Main St PLAN CHECK ENGINEER: Ahangian, KathyTEL:714 647-5812 EMAIL: Kahangian@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III A, SPK OCCUPANCY CLASSIFICATION(S): B, R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/5/2023 INITIAL REVIEW 11/3/2023 EXPIRATION 4/2/2024 RECHECKS: 1.1/3/24 PROJECT APPLICANT CONTACT PERSON: 2. Helen Becerra 3. TEL: (714)204-0077 FAX: VALUATION: $30,000.00 EMAIL: h.becerra@jb3d.com FLOOD ZONE: X-0602320276J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.CBC Sections A106.1 and A106.3.4.1, All drawings and supporting documents shall be prepared, stamped and signed by a California licensed architect or registered civil engineer.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuance - Information Technology equipment rooms require a completed electrical plan check prior to issuance of the building permit to ensure compliance with the 2022 California Electrical Code (CEC) Article 645, Electronic Computer/Data Processing Equipment. CEC Article 645 may require fire-rated walls, floors, and ceilings for the computer room(s). For additional information, contact Mr. Scott Davis, Electrical Plan Check at (714) 647- 5822.Provide complete calculation with engineering detail for the blade sign. Ok 1/10/24Provide dimension for the blade sign.Ok 1/10/24Provide calculation to justify existing framing members can carry additional load from the new 19’ tall sign (Laterally and vertically).Pending 1/10/24 please see comment # 12.Identify the sign on sheet 2.1.Is this a blade sign? Show the location.Ok 1/10/24Provide engineering calculation and attachment detail for the sign on sheet 2.1.Pending 1/10/24, On sheet SK-1 please clearly show location of new 4x6 posts in the wall framing and attachment detail at each story. ( Please identify new posts)