Loading...
HomeMy WebLinkAbout311616_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101117978 PROJECT ADDRESS: 2262 E Seventeenth St PLAN CHECK ENGINEER: Ahangian, KathyTEL:714 647-5812 EMAIL: Kahangian@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/16/2024 INITIAL REVIEW 1/20/2024 EXPIRATION 7/14/2024 RECHECKS: 1.2/21/24 PROJECT APPLICANT CONTACT PERSON: 2. Ali Mohammadi 3. TEL: (949)333-9322 FAX: VALUATION: $20,000.00 EMAIL: alim@acecapitaleng.com FLOOD ZONE: X-0602320164J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuancePlease identify all the walls on sheet AS1.2 which wall is new and which one is existing. For new walls, see comment #9. Pending 2/21/24Provide typical section view detail of all new partitions and ceilings showing:Pending 2/21/24, please identify which wall is new and which wall is existing. - Size, spacing, and material of framing members - Note gauge and ICC Research Report number and installation/construction requirements for metal framing members. - Method of attaching framing to the building structure. Compliance shall be shown with CBC Section 1607.13 for lateral support of the walls. Do not support top of walls to suspended ceiling system unless calculations and drawing prepared by a registered engineer are submitted for review. Submit structural engineering calculations for walls in rooms with a floor to building structure above height greater than 14’.Provide dimension and show location of the new hood.Ok 2/21/24Sheet AS1.2 is not clear, on equipment schedule please show which items are new and which one is existing. For new units provide information, show which one is part of this permit application.Pending 2/21/24Please revisit items descriptions, item # 69 is a cash register or a bathroom sink.Pending 2/21/24Provide weight of the hood on the drawings.Ok 2/21/24Provide lateral bracing for hanging rods on sheet S-2.Pending 2/21/24, provide diagonal bracing.Provide attachment detail for steel tube to the wood trusses.Ok 2/21/23Please pick up the red marks for clarification.