HomeMy WebLinkAbout309987_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101117494-95 PROJECT ADDRESS: 334 E Bishop St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/21/2023 INITIAL REVIEW 1/11/2024 EXPIRATION 5/19/2024 RECHECKS: 1.2/29/2024 PROJECT APPLICANT CONTACT PERSON: 2. Araceli Maciel 3. TEL: (714)285-1121 FAX: VALUATION: $8,500.00 EMAIL: aramaci65@gmail.com FLOOD ZONE: X-0602320276J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. -Grading Permit, if applicable. Application is made through the Building Safety Division (647-5800) and theplan review is by the Public Works Agency (647-5039). An application for a permit for any proposed work shall be deemed to have abandoned / expired after 180 days of the date of filing, unless such application has been issued. Sheet A-3: Please revise floor plan to show 2x6 stud walls at rear, right, and left walls as required by the Title 24 calculation for insulation thickness. 2nd Review Comment: Response was incomplete. In addition to the notes, please revise wall type to show exterior walls as 2x6 wall line (type). (Match wall thickness with 2x6 plumbing wall) Structural Review Comment: Sheet S-4 and S-3: Please revise framing plan and foundation plan to show 2x6 stud walls at rear wall, at right wall, and at left wall as required by the Title 24 calculation for insulation thickness. 2nd Review Comment: Response was incomplete. In addition to the provided notes – Please revise wall line to show 2x6 walls with 6x header and 2-2x6 studs at each end of shear wall panel. Reminder: Final plans shall be stamped, signed and dated by the engineer of records. (End of Comment)