HomeMy WebLinkAbout308951_6_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
104117180
PROJECT ADDRESS:
1659 E First St
PLAN CHECK ENGINEER:
Huang, GaryTEL:714
647-5862
EMAIL:
Ghuang@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
10/23/2023
INITIAL REVIEW
10/29/2023
EXPIRATION
4/20/2024
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Alicia Zamora
3.
TEL:
(949)244-2383
FAX:
VALUATION: $48,500.00
EMAIL:
alicia@anzamanagement.net
FLOOD ZONE: X-0602320276J
GUIDELINES:
Comments contained within this report reflect only those of the Building and Safety Division. Additional comments or corrective action may be required by other Departments and/or outside Agencies
This Plan Review Report and all subsequent code references are based upon the most recent version(s) of the 2022 California Building Codes (CBC, CRC, CFC, CEC, CPC, CMC, CGBSC, and CEES)
The approval of plans and any supporting documents does not permit the violation of any section of the adopted building codes or other pertinent local ordinances, or state and federal laws
All listed plan review comments must be adequately addressed before a building permit can be issued
Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.
PLAN REVIEW COMMENTS:
Applicant shall address all the checked‘☒’ correction comments below before resubmitting plans to Building Safety for recheck.
☒1. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process.
☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700).
☐Police Department approval on the corrected/final set of drawings (647-5840).
☒Public Works Agency approval (647-5039).
☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work.
☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).
☐Provide moisture barrier for the existing concrete slab. ☒Additional Review Comment:
Sheet A-0
Revised structural observation note item #1 and item #8 to City of Santa Ana instead of City of Los Angeles.
Building Data: revise occupancy to R-1. Based on City record, it is classify as a hotel/motel
Sheet S-0
Provide Seismic and Wind load design data per CBC 1603
Update all code reference per current CBC 2022
Sheet S-1
SEOR to provide calculation justify/demonstrate lateral resisting system of stair is adequate. Further review is required
SEOR to provide design loading criteria of the stair design (load take off)
Sheet S-2
Both detail 3 and detail 4 indicate that there is an existing beam show at floor level perpendicular to (E) walk way FJ. Show (E)beam on plan and indicate beam size
Sheet D-1
Detail 3: Plan show C12x20.7 beam next to (E) wood beam where meets the C12x stringer. Revise detail and indicate connection
Detail 4
Should the stringer be going in upper direction? Revise detail
Provide enlarge detail for how C12x stringer connected to C12 ledger
Provide bolt edge distance and spacing on C12 ledger beam
Detail 6: provide bolt spacing and edge distance of C6x to C12x
Detail 8: indicate shear plate to HSS post connection
Prior to submit the hard-copy drawings for approval and permit issuance. It is at applicant’s discretion, as an option, to submit a full-set electronic drawing (in pdf format) for a courtesy review. Please include the original red-marked comment drawing set, red-marked calculation, and all supporting document (revised calculation, etc.) for an expedite review.
Red marked comment set is available to pick-up at the City Hall.(End of Comment)