HomeMy WebLinkAbout313939_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101118685
PROJECT ADDRESS:
3506 W Lake Center Dr Unit# B
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B, SPK
OCCUPANCY CLASSIFICATION(S):
F-2
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
3/26/2024
INITIAL REVIEW
4/23/2024
EXPIRATION
9/22/2024
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Adel Bazzi
3.
TEL:
(562)755-9232
FAX:
VALUATION: $15,000.00
EMAIL:
adelbazzi@gmail.com
FLOOD ZONE: X-0602320258J
APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)An application for a permit for any proposed work shall be deemed to have abandoned / expired after 180 days of the date of filing, unless such application has been issued.Sheet T-1: Occupancy Group: Please specify occupancy group F-2 to match with existing occupancy classification. Sheet A-1.0: On the plan, please provide/show an accessible route complying with Section11B-402, from the public side walk and from accessible parking stalls to the accessible building primary entrance. Show on plan accessible route shall be 5% maximum slope, 2% maximum cross-slope, and 48” minimum clear width. On the plan, please show accessible parking stalls complying with 11B-502. Provide details with required dimensions, marking and signage. Details shall be clearly cross-referenced onto the plan. Show/provide detectable warning where required, and clearly cross-reference detail onto the plan. Sheet A-2.0: Partial floor plan is not acceptable. Please provide complete floor plans for the building. Plan review will continue at time of resubmittal. Additional comment may be required. On the plan, provide/show accessible restrooms in compliance with Chapter 11B, Division 6. Provide egress plan. New door and existing door in series – a 48” clear is required between door when door are opened in any position. On the plan, please specify electrical panel size (volts). Location and number of exit or exit access doorways shall be provided for electrical room in accordance with Section 110.26 and 110.33 of NFPA 70. Sheet D-1.0: Please clearly cross-reference details on sheet D-1.0 onto the plan. **Plan was incomplete. Plan review will continue at time of resubmittal and additional comment may be required.