HomeMy WebLinkAbout314869_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
104118990
PROJECT ADDRESS:
1523 E First St
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
4/22/2024
INITIAL REVIEW
5/13/2024
EXPIRATION
10/19/2024
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Vicky Li
3.
TEL:
(714)906-5714
FAX:
(888)473-9995
VALUATION: $8,000.00
EMAIL:
vincent@centralpacific-db.com
FLOOD ZONE: X-0602320276J
APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)An application for a permit for any proposed work shall be deemed to have abandoned / expired after 180 days of the date of filing, unless such application has been issued.Sheet A-1: Scope of work: Please revise scope of work to include the change of use from an office use to a beauty salon. On the plan, please provide the following: Applicable Codes: 2022 CBC, CEC, CMC, CPC, California Energy Code, California Green Building CodeOccupancy GroupsType of construction (V-B)Building areaThe accessible route should not include the stairway. For clarity, please show the accessible route (the dashed line) connecting the entry door to accessible ramp and to the public sidewalk. Please remove the vehicular gates. An accessible route is required from the public sidewalk to the rear building and from the accessible parking stalls to the office building accessible entrance. On the plan, please provide accessible parking stall and an accessible route to the office building entrance. Provide detail and clearly cross-referenced onto the plan. Sheet A-2: Reminder: Please transfer all handwritten notes onto the electronic file prior to printing.No opening shall be created on the East wall where fire-rated is required. Please relocate the AC split units. Floor plan: Please provide the following dimensionsShow dimension of 48” minimum hallwayShow dimension of 60” clear floor for the water closetShow dimension of 18” clear for the sink, measure from the centerline of the sink to the adjacent wallRoof plan: Please clarity whether the rooftop unit will be proposed or will be removed. Please coordinate with elevation; the elevation showed new AC unit on the roof. Provide structural calculation and roof framing plan and details to show support and anchorage for the proposed roof top unit. State all assumption. **Plan was incomplete. Plan review will continue at time of resubmittal and additional comment may be required.