Loading...
HomeMy WebLinkAbout308469_4_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101117041 / 42 / 43 PROJECT ADDRESS: 2201 S Hathaway St / 1335 E. Warner / 1339 E. Warner PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): S-1, B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/10/2023 INITIAL REVIEW 11/16/2023 EXPIRATION 4/7/2024 RECHECKS: 1.3/25/24 PROJECT APPLICANT CONTACT PERSON: 2.4/11/24 Chuck Marvick 3. TEL: (714)476-3829 FAX: VALUATION: $45,000.00 EMAIL: jcmarvick@sbcglobal.net FLOOD ZONE: X-0602320278J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)3rd Review Comment:Responses were incomplete. The following remain applicable and shall be addressed for building plan check approval. Please contact our permit technician with written request of changing the scope of works for infill the unpermitted openings between suites.Sheet SP-1.0: Please remove “NOT A PART” note on suite 1335 and 1339. Sheet SP-1.0: Please show infill wall between suites 1339 & 1341 (just below the restrooms)Sheet A-0.1: Minimum two (2) exit doorways are required for the warehouse space. Please revise egress plan to show/provide exit signs and exit doors go through the adjacent office 4 and out to the lobby area. The interior exit doors shall not be installed any locking devices.Sheet S-1: Please show infill wall at gridline 5 (between suite 1339 & 1341) – below the restroom. Sheet S-1: Referenced detail 10/SD-1 – Please reference to structural supporting detail for the new wall opening (strongback details). (End of Comment)