HomeMy WebLinkAbout315290_2_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
103119127
PROJECT ADDRESS:
626 S Harbor Blvd
PLAN CHECK ENGINEER:
Huang, GaryTEL:714
647-5862
EMAIL:
Ghuang@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
5/2/2024
INITIAL REVIEW
5/4/2024
EXPIRATION
10/29/2024
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Dong Nguyen
3.
TEL:
(714)724-2716
FAX:
VALUATION: $11,860.80
EMAIL:
dong3047@yahoo.com
FLOOD ZONE: X-0602320256J
GUIDELINES:
Comments contained within this report reflect only those of the Building and Safety Division. Additional comments or corrective action may be required by other Departments and/or outside Agencies
This Plan Review Report and all subsequent code references are based upon the most recent version(s) of the 2022 California Building Codes (CBC, CRC, CFC, CEC, CPC, CMC, CGBSC, and CEES)
The approval of plans and any supporting documents does not permit the violation of any section of the adopted building codes or other pertinent local ordinances, or state and federal laws
All listed plan review comments must be adequately addressed before a building permit can be issued
Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.
Applicant shall obtain clearance/approvals from following departments after obtaining approval from Building and Safety Division, prior to building permit issuance
☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process.
☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700).
☐Police Department approval on the corrected/final set of drawings (647-5840).
☐Public Works Agency approval (647-5039).
☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work.
☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).
Applicant must pick up red marked sheet from the City prior to resubmittal and return marked up set with resubmittal.
PLAN REVIEW COMMENTS:Sheet A0.0Verify structure’s construction type. Should it be either VA or VB?[Comment resolved]Sheet A3.0Indicate the existing travel distance (in feet) from the most remote location of the (N) storage to the closest exist to public way. The path of travel may be represent using arrows [Comment resolved]Revise (E) storage to (N) storage. Since the scope of work is to legalize unpermitted construction, thus everything should be indicate as a new construction[Comment resolved]Indicate 18” minimum distance for front approach, pull side [Comment resolved]Provide minimum 48” clear approach distance. [Comment not resolve – previous comment, provide/indicate on plan minimum 48” required for clear approach distance]Sheet A4.0provide the spacing of 2x4 vertical stud[Comment resolved]indicate on plan the building roof height [Comment resolved]indicate on plan the ceiling height[Comment resolved]Provide construction detail for how acoustic tile ceiling attachment to roof framing, including hanger wire size, spacing, diagonal wire and etc. [Comment resolved] Provide construction details 2x4 diagonal bracing attachment to both the roof and the vertical stud[Comment resolved]Provide construction details for vertical stud to slab on grade[Comment resolved]
2ndPLAN REVIEW COMMENTS (5/21/2024):Sheet A2.0Verify background with sheet A3.0 and revise background to match with each otherSheet A4.0Detail C:Provide connection for metal stud bract to wood roof joist connection Provide enlarge detail for metal stud brace to wood wall stud connection Clarify what is “L.W.” abbreviationProvide/specify post install anchor bolt manufacture and ICC ESR report number with minimum embedment (End of Comment)