Loading...
HomeMy WebLinkAbout316039_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101119364 PROJECT ADDRESS: 713 N Newhope St PLAN CHECK ENGINEER: Huang, GaryTEL:714 647-5862 EMAIL: Ghuang@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): A-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 5/22/2024 INITIAL REVIEW 7/3/2024 EXPIRATION 11/18/2024 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Giep Van Le 3. TEL: (323)537-5874 FAX: VALUATION: $4,000.00 EMAIL: legiep49@gmail.com FLOOD ZONE: A-0602320143J GUIDELINES: Comments contained within this report reflect only those of the Building and Safety Division. Additional comments or corrective action may be required by other Departments and/or outside Agencies This Plan Review Report and all subsequent code references are based upon the most recent version(s) of the 2022 California Building Codes (CBC, CRC, CFC, CEC, CPC, CMC, CGBSC, and CEES) The approval of plans and any supporting documents does not permit the violation of any section of the adopted building codes or other pertinent local ordinances, or state and federal laws All listed plan review comments must be adequately addressed before a building permit can be issued Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used. Applicant shall obtain clearance/approvals from following departments after obtaining approval from Building and Safety Division, prior to building permit issuance ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☐Public Works Agency approval (647-5039). ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039). Applicant must pick up red marked sheet from the City prior to resubmittal and return the marked up set with resubmittal PLAN REVIEW COMMENTS: Sheet A-1 Project information: Revise occupancy to A3 Revise applicable code to 2022 CBC Sheet S1 General comment: Remove steps (detail 3/S1 and on foundation plan, section A) or provide accessible ramp comply with 11B-405 and provide warning curb comply with 11B-303.5 Design parameter Include medication factor, Rp & amplification factor ap, on plan per calculation Revise total design weight. Design weight is 55116 lb per calculation Detail 2 Provided post-installed anchor bolt (item #2) minimum embedment depth into footing Per calculation footing based depth below soil surface starts at 1.5 ft. Revise 8” as indicated per detail to 1.5 ft Per calculation footing depth is 24 inches deep. It is consider from footing base depth per item 2aii (above). Revise footing depth Detail note #4, specify minimum 7 rebar required per calculation Foundation Plan Specify anchor bolt size, spacing and provide structural calculation for justification Show line of footing based (detail 2/S1) on foundation plan Red marked comment set is available to pick-up at the City Hall.(End of Comment)