HomeMy WebLinkAbout314017_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101118720
PROJECT ADDRESS:
1938 E Warner Ave Bldg# P
PLAN CHECK ENGINEER:
Lo, JonathanTEL:714
647-5822
EMAIL:
Jlo@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
I B, SPK
OCCUPANCY CLASSIFICATION(S):
A-3, S-2
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
4/10/2024
INITIAL REVIEW
4/11/2024
EXPIRATION
10/7/2024
RECHECKS:
1.6/6/2024
PROJECT APPLICANT CONTACT PERSON:
2.
Heidi Hare
3.
TEL:
(949)246-0492
FAX:
VALUATION: $15,000.00
EMAIL:
heidi@jlhare.com
FLOOD ZONE: X-0602320279J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment.
The applicant shall obtain clearances/approvals for the following after obtaining approval from Building and Safety Division, prior to building permit issuance (CHECKED BOXES REQUIRED ONLY):
☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process.
☐Public Works Agency approval (647-5039).
☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700).
☐Police Department approval on the corrected/final set of drawings (647-5840).
☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work.
☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. Applicant must pick up red marked sets from city prior to resubmittal and return marked up set with resubmittal.DocumentationPermit application and set are separate from originally approved permit drawings. Please provide the following on drawing set:Title/Cover SheetRough Site Plan/ Floor Plan showing area of workProvide associated notes as well as structural material notes.DrawingsSheet GS8.1Detail 1 – Verify HSS post size specified with plans, currently do not match.Detail 2 – Verify HSSS post size specified with plans, currently do not match.Detail 6 – Detail references 17/GS1.2. All referenced sheets shall be provided in this set.Detail 18 – Detail references Roof Beam per plan, no plan is found for fireplace framing.Detail 18 – Metal stud infill not found in Landscape drawings, please coordinate with arch and provide in set.PC #2: Permit for fire place construction shall contain all information required for permitting including metal stud information. If information is found on original permit, please reference. Applicant is responsible for organizing and providing all required information for design and construction and shall coordinate with design teams to ensure required/requested information is provided.Sheet GS8.2Detail 1 – Verify HSS 12x12 member specified on left side.Detail 3 – Provide detail for interior fascia connection to main HSS members.PC #2: Detail for interior 2x12 HSS to 6x8 HSS connection is not found in Landscape architect drawings. Applicant is responsible for organizing and providing all required information for design and construction and shall coordinate with design teams to ensure required/requested information is provided.Detail 3 – Specify interior fascia member sizes on plans or reference where found.Detail 3 – Provide calculation design for interior fascia members spanning across opening length. Verify member is supporting panel load.Detail 3 – Provide corner connection detail at structure fascia members. Detail 18 – Verify detail sheet references in detail bubbles. Sheet LC.9Verify roof structure shown at fireplace in Overall View. No plans have been provided. Coordinate with Structural for design. PC #2: Comment not addressed.CalculationsProvide design for wind loading on roof top structures.Provide lateral design for roof top structures.Overhead Trellis – Provide design for 8’-4” cantilever condition as shown on drawing set.(End of Comment)