HomeMy WebLinkAbout316345_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101119472 PROJECT ADDRESS: 2115 N Broadway PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V A, SPK OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/3/2024 INITIAL REVIEW 6/13/2024 EXPIRATION 11/30/2024 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Jessica Smarker 3. TEL: (805)444-8677 FAX: VALUATION: EMAIL: jsmarker@hhendy.com FLOOD ZONE: X-0602320163J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.INSTRUCTIONSAll items noted on this plan check report must be addressed.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used. All drawings and supporting documents shall be prepared, stamped, and signed by a California licensed architect or registered professional engineer. (CRC R301.1.3, CBC 107.1 and 107.3.4.1). This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. PLAN CHECK COMMENTS Sheet 1A-T. For scope of work description title, please add bulletin #3 and bulletin #4 as part of the permit # 101116375 on plan. Please provide scope of work description and bulletin # for this permit on plan. Sheet 1A-6.3 Please provide the UL #W419 approved tested details on plan. Please provide the UL #I516 approved tested details on plan. Wall section detail 1. Provide 1-hour minimum fire caulking material with ICC or UL # on plan at the top and bottom of the full-height glass wall around the atrium on plan. Wall section detail 1. Revise wall section on to provide continuous 1-hour minimum fire barrier/horizontal assembly from top of the glass wall to the underside of the roof sheathing on plan. Joints and voids at intersections shall comply with Sections 707.8 and 707.9 (CBC 404.5 exception 2) Provide structural design for the new furred soffit walls that are connected at the top and bottom provided sufficient lateral and vertical support by the building framing. Specify ICC number on the members, fasteners and attachments on plan. END OF COMMENTS