Loading...
HomeMy WebLinkAbout315029_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 104119039 PROJECT ADDRESS: 716 S Main St PLAN CHECK ENGINEER: Ahangian, KathyTEL:714 647-5812 EMAIL: Kahangian@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 4/25/2024 INITIAL REVIEW 5/29/2024 EXPIRATION 10/22/2024 RECHECKS: 1.6/20/24 PROJECT APPLICANT CONTACT PERSON: 2. Vicky Li 3. TEL: (714)906-5714 FAX: (888)473-9995 VALUATION: $5,000.00 EMAIL: vincent@centralpacific-db.com FLOOD ZONE: X-0602320276J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.Clearly indicate the scope of work under this building permit on the cover sheet. - Revise project job description on the building permit application worksheet to reflect the work to be done under the subject building permit application.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceDrawings must be to scale and be on 18” x 24” minimum sheets. Ok 6/20/24 - Provide a Vicinity Map showing project locationProvide the following:Pending 6/20/24 Remove truncated domes - Disabled access compliance must be shown on the site plan.Show on the plans:Ok 6/20/24 - Project Address/Suite/Room Numbers; Building Numbers for each building - Occupancy Classification(s) - Type of ConstructionCBC Section 1013.1. Provide a directional exit sign at changes in exiting direction.Ok 6/20/24Tactile exit signs shall be required at the following locations:Ok 6/20/24 - Each grade-level exterior exit door shall be identified by a tactile exit with the word “EXIT.”Drawings submitted to the Building Division for review shall provide the following information to insure compliance with CBC Section 11B-202.4: - An accessible entrance - An accessible route to the altered area - Accessible restroomsPending 6/20/24 Make a note on the drawings and provide a letter that the building will not be occupied before future TI.If a walk crosses or adjoins a vehicular way, and the walking surfaces are not separated by curbs, railings or other elements between the pedestrian areas and vehicular areas, the boundary between the areas shall be defined by a continuous detectable warning which is 36” wide, complying with the CBC section 11B-247.1.2.5Pending 6/20/24, Truncate domes cannot be in the middle of driveways.Provide structural calculations and drawings, stamped and signed by a California licensed architect or registered civil engineer for:Ok 6/20/24 - New mechanical equipment on roof (note on Roof Framing Plan weight of each existing and new piece of equipment on the roof) - New equipment screening on roofIt shows 2 accessible parking on detail 1, please revise site plan to match detail 1.Ok 6/20/24Is there any curb ramp from parking lot to the sidewalk and to the store, if there is provide detail.Ok 6/20/24Provide minimum one (1) separate wash basin in each massage establishment for the use of employees provide soap and hot water.Ok 6/20/24Provide furniture plan in the break room.Ok 6/20/24Provide roof plan per planning requirement and show the roof top units.Ok 6/20/24Provide roof screening per planning , if you feel the item is not applicable please see planning.Ok 6/20/24 Please fill out attached Accessible compliance form.Pending 6/20/24 Please identify on the drawings accessible improvement per Disabled Access Form.