HomeMy WebLinkAbout316976_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101119672 PROJECT ADDRESS: 1606 S Evergreen St PLAN CHECK ENGINEER: Huang, GaryTEL:714 647-5862 EMAIL: Ghuang@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): U, R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/19/2024 INITIAL REVIEW 6/22/2024 EXPIRATION 12/16/2024 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Mike Hokama 3. TEL: (714)573-0073 FAX: VALUATION: $40,000.00 EMAIL: hchansen@msn.com FLOOD ZONE: X-0602320276J GUIDELINES: Comments contained within this report reflect only those of the Building and Safety Division. Additional comments or corrective action may be required by other Departments and/or outside Agencies This Plan Review Report and all subsequent code references are based upon the most recent version(s) of the 2022 California Building Codes (CBC, CRC, CFC, CEC, CPC, CMC, CGBSC, and CEES) The approval of plans and any supporting documents does not permit the violation of any section of the adopted building codes or other pertinent local ordinances, or state and federal laws All listed plan review comments must be adequately addressed before a building permit can be issued Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used. Applicant shall obtain clearance/approvals from following departments after obtaining approval from Building and Safety Division, prior to building permit issuance ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☐Public Works Agency approval (647-5039). ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039). Applicant must pick up red marked sheet from the City prior to resubmittal and return the marked up set with resubmittal PLAN REVIEW COMMENTS: Sheet 2 Walls separating dwelling units (Unit B and Unit C) shall provide airborne sound insulation for walls with an STC rating of at least 50 per. Provide details on plans and provide verification of a tested assembly to achieve the required STC rating of 50. Misc. notes #4: provide missing detail M/5 for review Sheet 3 Misc. notes #5 provide missing detail M/5 for review Legend: provide missing detail K/5 and L/5 for review Sheet 4 Partial roof framing plan: New roof sheathing note: verify detail reference callout for plywood layout diagram legend: provide missing detail H/4 for review, and verify detail reference Detail A: verify detail reference, should detail E/5 be detail D/5 verify detail reference, should detail G/5 be detail F/5 Detail B: verify detail reference, should detail F/5 be detail E/5 verify detail reference, should detail H/5 be detail G/5 provide missing detail M/5 for review Sheet 5 Detail D: provide detail connection showing how (E) stud supporting (N) roof rafter Detail G: provide missing detail M/5 for review Detail J: provide missing section cut X-X for review (End of Comment)