HomeMy WebLinkAbout317212_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101119728 PROJECT ADDRESS: 3501 W Sunflower Ave PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/25/2024 INITIAL REVIEW 6/30/2024 EXPIRATION 12/22/2024 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Dominique Mosqueda 3. TEL: (949)698-0017 FAX: VALUATION: $65,000.00 EMAIL: dmosqueda@emcor.net FLOOD ZONE: X-0602320258J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment. The applicant shall obtain clearances/approvals for the following after obtaining approval from Building and Safety Division, prior to building permit issuance (CHECKED BOXES REQUIRED ONLY): ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☒Public Works Agency approval (647-5039). ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☒Police Department approval on the corrected/final set of drawings (647-5840). ☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. Applicant must pick up red marked sets from city prior to resubmittal and return marked up set with resubmittal.CalculationsSheet 9 of 28 – Verify # of anchors in Tension at unit to curb connection with drawings. Anchor number does not look to match. Sheet 10 of 28 – Verify # of anchors in Shear at unit to curb connection with drawings. Anchor number does not look to match. Sheet 12 of 28 – Verify Moment Arm applied in calculation. Drawing specifies 60” Maximum curb height. 60” curb height + unit C.G. looks to be more than 70” used. Sheet 15 of 28 – Verify Moment Arm applied in calculation. Drawing specifies 60” Maximum curb height. 60” curb height + unit C.G. + sleeper depth looks to be more than 85” used.Sheet 15 of 28 – Verify # of anchors in Tension in the Y Direction at sleeper to concrete pad connection with drawings. Anchor number does not look to match. Sheet 18 of 28 – Provide combined interaction for screw design at curb to sleeper. (End of Comment)