Loading...
HomeMy WebLinkAbout318994_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101120343 PROJECT ADDRESS: 2717 N Lyon St PLAN CHECK ENGINEER: Huang, GaryTEL:714 647-5862 EMAIL: Ghuang@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/7/2024 INITIAL REVIEW 8/15/2024 EXPIRATION 2/3/2025 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Alex Pardee 3. TEL: (949)683-9861 FAX: VALUATION: $15,000.00 EMAIL: paul@DPSpermits.com FLOOD ZONE: X-0602320163J GUIDELINES: Comments contained within this report reflect only those of the Building and Safety Division. Additional comments or corrective action may be required by other Departments and/or outside Agencies This Plan Review Report and all subsequent code references are based upon the most recent version(s) of the 2022 California Building Codes (CBC, CRC, CFC, CEC, CPC, CMC, CGBSC, and CEES) The approval of plans and any supporting documents does not permit the violation of any section of the adopted building codes or other pertinent local ordinances, or state and federal laws All listed plan review comments must be adequately addressed before a building permit can be issued Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used. Applicant shall obtain clearance/approvals from following departments after obtaining approval from Building and Safety Division, prior to building permit issuance ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☐Public Works Agency approval (647-5039). ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039). Applicant must pick up red marked sheet from the City prior to resubmittal and return the marked up set with resubmittal PLAN REVIEW COMMENTS:Sheet 1Please specify enclosed patio roof slope on the plan, and on the elevationSheet 3Please specify enclosed patio roof slope on the planPlease provide construction detail for how existing roof cricket is connect to new patio roof framing Sheet LRP-3Please note and revise basic wind speed to 95 mphPlease enter appropriate design “applied load” under Step 2EPlease update all changes (highlight) based on appropriate wind speed criteria at 95 mphSheet LRP-4ABased on appropriated design “applied load”, the selected maximum panel span under step III does not work for 4” member. Please revise and select based on the appropriate applied load Sheet LRP-6Provide/revise determine allowable width per corrected wind loadProvide selection for Step IV-B for seismic analysis Sheet LRP-7Provide selection for Step VI for allowable gable beam span Provide selection for footing size under Step VIISheet E40-4 to Sheet E40-8Provide/revise selection based on the appropriate wind load at 95 mph.(End of Comment)