HomeMy WebLinkAbout317810_3_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101119943 -46
PROJECT ADDRESS:
1810 E First St
PLAN CHECK ENGINEER:
Ahangian, KathyTEL:714
647-5812
EMAIL:
Kahangian@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
N/A
OCCUPANCY CLASSIFICATION(S):
N/A
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
7/10/2024
INITIAL REVIEW
7/26/2024
EXPIRATION
1/6/2025
RECHECKS:
1.8/22/24
PROJECT APPLICANT CONTACT PERSON:
2.
Sandy Zundell
3.
TEL:
(949)296-2400
FAX:
VALUATION: $35,000.00
EMAIL:
sandy@brandywine-homes.com
FLOOD ZONE: X-0602320277J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.
Please see corrections on submitted plans. Red marked set must be returned with revised plans. Plans resubmitted without the red markup set may result in delayed review time and additional plancheck fees.
All drawings and supporting documents shall be prepared, stamped, and signed by a California licensed architect or registered professional engineer. (CRC R301.1.3, CBC 107.1 and 107.3.4.1).Landscape licensed architect cannot stamp the architectural drawings.Pending 8/22/24
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
- Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
Where does gate shown on LC-2.01, lead to (at the property line), provide landing at each side and show compliance with accessibility to include the latch height.Ok 8/22/24
Building 1818 is not part this review; please remove all items related to 1818 from this drawings.Ok 8/22/24
Show gates for adaptable units comply with accessibility.Pending 8/22/24, why detail 9/ LC5.04 removed.
Please remove details for items that are not part of his permit application, including BBQ stand and mail boxes.
Provided gate detail 4/ LC-5.04 doesn’t comply with accessibility.
Detail for block fence removed, please verify if perimeter fencing is part of this permit? If it is provide depth of the footing.