HomeMy WebLinkAbout321654_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101121200 PROJECT ADDRESS: 2527 W Camden Pl PLAN CHECK ENGINEER: Huang, GaryTEL:714 647-5862 EMAIL: Ghuang@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/16/2024 INITIAL REVIEW 11/2/2024 EXPIRATION 4/14/2025 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Conrad Chapa 3. TEL: (714)653-0794 FAX: VALUATION: $5,000.00 EMAIL: conrad@1stoproofing.com FLOOD ZONE: X-06059C0257J GUIDELINES: Comments contained within this report reflect only those of the Building and Safety Division. Additional comments or corrective action may be required by other Departments and/or outside Agencies This Plan Review Report and all subsequent code references are based upon the most recent version(s) of the 2022 California Building Codes (CBC, CRC, CFC, CEC, CPC, CMC, CGBSC, and CEES) The approval of plans and any supporting documents does not permit the violation of any section of the adopted building codes or other pertinent local ordinances, or state and federal laws All listed plan review comments must be adequately addressed before a building permit can be issued Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used. Applicant shall obtain clearance/approvals from following departments after obtaining approval from Building and Safety Division, prior to building permit issuance ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☐Public Works Agency approval (647-5039). ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☒Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039). Applicant must pick up red marked sheet from the City prior to resubmittal and return the marked up set with resubmittal PLAN REVIEW COMMENTS:Sheet A1Revise all referenced cade to 2022 edition of California Building CodeSection B: provide construction details for back patio rafter to girder and girder to post connection Section D:Provide construction details for ledger to wall connection Provide construction details for patio rafter to girder, and girder to post connectionFooting details:Provide clear/legible footing size for reviewProvide post to footing connection Specify and reference on plan which post to footing hardware to be used for each of side patio and back patioProvide clear/legible print for the brace design and dimension for reviewFor both patio: are there new slab-on-grade? If so, specify slab thickness on planSheet S1Provide back patio roof joist size and spacing, girder size, post size, ledger beam size on plan Provide side patio roof joist size and spacing, girder size, post size on plan Provide structural design calculation for girder design for review Specify on plan the slope of both back patio and side patio(End of Comment)