HomeMy WebLinkAbout317431_3_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
104119801
PROJECT ADDRESS:
3122 S Halladay St
PLAN CHECK ENGINEER:
Ahangian, KathyTEL:714
647-5812
EMAIL:
Kahangian@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B, M
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
7/1/2024
INITIAL REVIEW
7/7/2024
EXPIRATION
12/28/2024
RECHECKS:
1.9/4/24
PROJECT APPLICANT CONTACT PERSON:
2.11/13/24
Aaron Baggaley
3.
TEL:
(916)502-0467
FAX:
VALUATION: $10,000.00
EMAIL:
aaron@deltagc.com
FLOOD ZONE: X-0602320278J
APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.Clearly indicate the scope of work under this building permit application:
- Revise project job description on the building permit application worksheet to reflect the work to be done
under the subject building permit application. ( To include changing wood door with electric metal door)This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuancePer code enforcement citation, a wood door replaced by an electric metal door , please show on the floor plan.Ok 9/4/24Provide all requirements per CBC for the electric door. Pending 9/4/24, Show all the exit doors and show they are openable from inside without use of any key or knowledge, provide requirements from CBC 1010.2.12Ok 11/13/24Is it a door with a card reader? If it is show compliance with CBC 2022.Pending 9/4/24, provide height of the card reader. Provide requirements from CBC 1010.2.11.Ok 11/13/24CBC 11B-303, Regardless of the occupant load, there will be a floor landing at each side of the door. And show threshold complies with accessibility.Pending 9/4/24, Not foundPending 11/13/24, remove truncated domes at the landings at the door.CBC Section 11B-404.2.7.Hand-activated door opening hardware shall be centered between 30” and 44” above the floor. Latching and locking doors that are hand activated and which are in a path of travel shall be operable with a single effort by lever-type hardware, by panic bars, push-pull activating bars, or other hardware designed to provide passage without requiring the ability to grasp the opening hardware. Locked exit doors shall operate as above in egress direction.Ok 9/4/24CBC Section 11B-404.2.9, Note on the drawings: “Maximum effort to operate doors shall not exceed 5 pounds for exterior doors and interior doors, such pull or push effort being applied at right angles to hinged doors and at the center place of sliding or folding doors. Compensating devices or automatic door operators may be utilized to meet the above standards. Ok 9/4/24Complete the attached Disabled Accessibility Documentation Form.Pending 11/13/24 9/4/24 Call out all new and existing card readers on the floor plan.Pending 11/13/24, No card reader allowed at the exit doors, remove card reader from door D-13. 11/13/24 Due to adding to the scope of work at the 3rd round of resubmittal please see below comments.Provide minimum 12” clearance at the strike edge of door # 14,Please see planning for increasing sales area by removing partition walls.