HomeMy WebLinkAbout322605_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101121524
PROJECT ADDRESS:
1442 S Bristol St Unit# 2-C
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
11/7/2024
INITIAL REVIEW
11/17/2024
EXPIRATION
5/6/2025
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
A C Atherton
3.
TEL:
(949)613-4745
FAX:
VALUATION: $80,910.00
EMAIL:
aca@summit7d.com
FLOOD ZONE: X-06059C0257J
APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Fire Department approval on the corrected/final sets of drawings ((714)573-6100)
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)
- County of Orange Health Department approval on the corrected/final set of drawings ((714)433-6000)Sheet G000:Occupancy Group: Please revise plan to specify occupancy group ‘B’. It’s a restaurant (serving food) with not more than 49 occupants. Site plan: In addition to the reference to detail 1/A0.1 for the parking stall, please reference to detail 5/A0.1 for parallel curb ramp and truncated dome. (see marked up plan)Sheet A1.0: Floor plan: Existing 4-ft walkway – Please revise plan to provide door swing inward; otherwise, a 5-ft landing for maneuvering clearance is required on the pull side (walkway). Service counter: Please specify 34” maximum height for the service counter. New wall: Please provide detail for new wall construction. Detail shall be clearly cross-reference onto the plan. Kitchen hood: Combustible wall located adjacent to the type I hood – Please build out metal stud wall furred out to protect type I hood from the existing combustible wall (wood stud wall). Structural Comment:Kitchen hood: Please provide structural calculation and detail for the hood support. Provide roof framing and detail to show support of new roof top equipment. Provide calculation. Provide detail for new walk-in cooler anchorage. Final plan and calculation shall be stamped, signed and dated by a California registered civil engineer.