HomeMy WebLinkAbout325757_1_Corrections.docxPLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101122518
PROJECT ADDRESS:
320 W Fourth St
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
N/A
OCCUPANCY CLASSIFICATION(S):
N/A
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
2/13/2025
INITIAL REVIEW
3/13/2025
EXPIRATION
8/12/2025
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Frankie Mata
3.
TEL:
(714)478-2304
FAX:
VALUATION: $100,000.00
EMAIL:
frankie@mdmmasonry.com
FLOOD ZONE: X-06059C0276J
APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)
- Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by
the Public Works Agency (647-5039)Grading permit is required for the proposed project. Grading permit shall be issued prior to building permit issuance. Sheet C-1: Plan shall be stamped, signed by the licensed architect or register civil/structural engineer. Sheet C-1: On the plan, please clearly specify the use of the proposed leveled backfill pad/slab. Sheet C-1: Please revise plan to specify 10-ft height retaining wall (match with structural details). Sheet C-1: Please revise plan to show new retaining wall extend to the rear property line (match structural plans); otherwise, check existing wall and footing for the retaining loads. Sheet C-1: Please note on plan “Retaining wall backfill should be compacted to a minimum of 90 percent of the maximum dry density as determined by ASTM D 1557-12. The compaction report shall be presented to the building inspector, and shall be provided prior to pouring concrete slab.”Soil report: Please update/provide soil report for the job address 320 W. Fourth Street. Revise soil report and subject to reflect the proposed retaining wall and backfill. Provide design parameters for the proposed 12-ft height retaining wall (see plans). Final plan shall be submitted to the soil engineer for review and approval. The soil engineer shall “review” stamp the plans for general conformance with the soil investigation and recommendations. Sheet S-1: Per structural design, the retaining wall and the backfill was not designed for any future development. Clearly note on plan “The retaining walls and footings were not designed for any future development”. If the proposed flat will be used for parking, walls shall be designed with vehicle loadings and shall be marking/striping for accessible parking stalls and access route. Sheet S-1: On the plan, please specify how deep the existing soil will be excavated for the proposed retaining wall footing. Sheet S-1: On the plan, please clearly show property lines. Sheet S-1: Retaining wall details Please revise details to show property line in relative to the proposed retaining wall. Revise details to show location of wall and foundation lines of existing adjacent buildings. New retaining walls shall not surcharge onto the existing adjacent wall and foundation. Show structural separation between the new retaining wall and existing wall and foundation. Details: Please show/specify different wall thickness for the bottom wall stem. Retaining wall calculation: Provide/show calculation for the maximum deflection of the retaining wall. Structural separation is required between the new retaining wall and existing building walls and foundation. Wall adjacent to the street and alley: Please verify whether there was existing retaining walls along the 4th street and back alley. Provide section/detail to show existing retaining wall street and alley finished grade in relative to the proposed back-fill.Verify if there is any basement wall locate along the street and alley side. (End of comment)