HomeMy WebLinkAbout326129_2_Corrections.docxSPC PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101122631 PROJECT ADDRESS: 1411 N Broadway PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): A-3, B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 2/25/2025 INITIAL REVIEW 2/25/2025 EXPIRATION 8/24/2025 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Heidi Hare 3. TEL: (949)246-0492 FAX: VALUATION: EMAIL: heidi@jlhare.com FLOOD ZONE:X-06059C0163J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804).Show top landing depth on the site plan.Missing top handrail extensions on both sides of the ramp. Ramp handrails shall extend horizontally above the landing for 12 inches minimum beyond the top and bottom of ramp runs in the direction of ramp run (no 90 degree turns). Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run. §11B-505.10.1. See redlines on plan.Provide architectural sheets showing ramp handrail design on this submittal document. E.g. sheet A004.Please coordinate with civil engineer to have consistent ramp design with revised architectural site plans. E.g. dimensions, handrails…END OF COMMENTS