HomeMy WebLinkAbout326427_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101122722-26
PROJECT ADDRESS:
1715 E Wilshire Ave Building # 7
PLAN CHECK ENGINEER:
Lee, WayneTEL:714
647-5848
EMAIL:
wlee@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
III B
OCCUPANCY CLASSIFICATION(S):
B, S-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
3/5/2025
INITIAL REVIEW
3/21/2025
EXPIRATION
9/1/2025
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Bryan Montoya
3.
TEL:
(949)251-1710
FAX:
(949)225-1400
VALUATION: $90,000.00
EMAIL:
bryan@cadtronics.net
FLOOD ZONE: X-06059C0277J
APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please return marked up set of drawings with corrections.The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2022 California Building Standards Code with local amendments.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)See additional comments marked on the drawings.Multiple sheets. Revise title block on each sheet to show complete address:” 1715 East Wilshire Ave Building 7, suite 704, 705, 713, 714, 716, 717, 723, 724, Santa Ana, CA. 92705”.Multiple sheets. Please identify the correct unit address number after combination or alteration. Remove deactivated addresses on plan. Revise plan. See redlines on plan.Old addressNew address#704, #705#704#713, #716, #717#713#714#714#723, #724#723Add a new sheet to show complete proposed floor plan for the entire building.Sheet T1.See red lines on plan under building data. Clarify the area breakdown which does not match the overall square footage.Sheet T1. Delete California historical building code which does not apply to this project.Sheet HC1. Please identify and label the property lines to identify the boundaries of the lot.Sheet A2 through A4. Show correct drawing scale on plan.Sheet D1. Detail 8. Provide complete attachment design to provide lateral support at the top of the partition wall. Specify type, spacing, and embedment of the fasteners.Means of egressSheet A3. See redlines on plan. In suite 713, please use right-angle method to calculate the travel distance (200 feet max) and common path of travel (100 feet max) in warehouse area. It appears the common path of travel may exceed 100 feet, provide and identify two means of egress from the remotes point to building exit. Provide exit signage. (illuminate sign and tactile sign)AccessibilityProvide parking space calculation for the entire lot. Provide a table to show the number of parking spaces information provided on plan:Number of spacesParking spaces (not included accessible spaces)Van accessible parking spacesStandard accessible parking spacesTotal parking spacesIdentify each accessible parking space on the site plan. Label van and standard accessible parking space.Sheet HC1.1 and HC1.2- See redlines on planProposed site shall not decrease the existing accessibility. On the south side of the lot where existing accessible route and two parking spaces are removed, provide compliant accessible route and two accessible parking spaceat or near the existing location.Please maintain the same level of the dispersion of accessible parking spaces serving multiple suites. Provide accessible parking space at or near the same location of all existing accessible parking spaces.Show width and length of the ramp and landing of the curb ramps. Provide dimensions on the site plan.Sheet HC1.1. The access aisle shall be on the passenger side of the van accessible parking space.Sheet HC1.3. Detail 4. Revise the mounting height to be measured to the bottom of the lowest signage from the ground surface.Sheet HC2. Revise “Disable access compliance documentation form”. The adjusted cost of construction shall include all permits (#101122722 through #101122726). Please update the form and show compliance.