HomeMy WebLinkAbout327389_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101123080 PROJECT ADDRESS: 5124 W Roberts Dr PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/27/2025 INITIAL REVIEW 4/29/2025 EXPIRATION 9/23/2025 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Ricky Yu 3. TEL: (714)880-9100 FAX: VALUATION: $160,000.00 EMAIL: novastarrealty@gmail.com FLOOD ZONE: X-06059C0256J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. Sheet G1: On the plan, please provide new ADU to existing house floor area ratio, for the purpose of calculating Park & Rec fee, (800 sq.ft / 2248 sq.ft. = 0.36). Electrical panel: Please show electrical compliance with Energy Storage System required by the Energy Code. Please reproduce the Detached ADU Grading Permit Waiver Request on the plan. Please verify and specify on the plan whether the existing house is equipped with Automatic Fire Sprinkler or not. On the plan, please show/provide main electrical service panel with minimum 225 amp busbar rating. Sheet T-1: Title 24 CF1R (page 3 of 11): The form indicated Battery as design source – Please clearly specify on the Title sheet G1 battery storage is proposed and will be submitted together with the PV submittal. Otherwise, revise Title 24 calculation accordingly. Title 24 must be registered to a HER provider; the form should bear the watermark of the provider (CHEER). Sheet A-1: The 34” door for bedroom #2 and bathroom #2 would not provide the required 32” net clear opening. Please use 3-ft wide doors. On the plan, please provide/show door landing for exterior doors. Sheet A-2: Range hood: Please revise to provide 280 cmf exhaust hood minimum. Sheet A-3: Elevation note #11: On the plan, please specify maximum weight of the tile roof. Sheet S-1: Roof diaphragm was exceeding 3:1 (L/W) ratio. Please provide interior shear wall and footing. Provide details for shear transfer for interior shear wall for transfer of lateral loads from roof to wall to foundation. Revise calculation for the required interior wall. Submit foundation plan to the geotechnical engineer for review and approval. The geotechnical engineer shall “review” stamp the plan for compliance with the soil report finding and recommendation. (End of Comment)