HomeMy WebLinkAbout326934_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101122886 & 87 PROJECT ADDRESS: 31 E MacArthur Crescent Unit# 301 Bldg# H PLAN CHECK ENGINEER: Ahangian, KathyTEL:714 647-5812 EMAIL: Kahangian@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: I A, SPK OCCUPANCY CLASSIFICATION(S): R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/18/2025 INITIAL REVIEW 4/14/2025 EXPIRATION 9/14/2025 RECHECKS: 1.5/12/25 PROJECT APPLICANT CONTACT PERSON: 2. Alberto Dulay 3. TEL: (562)508-5941 FAX: VALUATION: $5,000.00 EMAIL: adulay@next-arc.com FLOOD ZONE: X-06059C0278J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment. Please see corrections on submitted plans. Red marked set must be returned with revised plans. Plans resubmitted without the red markup set may result in delayed review time and additional plancheck fees. All drawings and supporting documents shall be prepared, stamped, and signed by a California licensed architect or registered professional engineer. (CRC R301.1.3, CBC 107.1 and 107.3.4.1). This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. -Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039). Show one of the bathrooms in unit 301 complies with accessibility.Pending 5/12/25, show the cabinet under the sink will be removable without use of tools or special knowledge. Identify all items in bathroom #1 in unit 301. Show clear dimensions for all the toilets . Provide grab bar for each toilet. Provide minimum 44” landing at each side of interior doors. Provide clear floor at the kitchen sinks. Pending 5/12/25, cabinet under the kitchen sink shall be readily removable. Provide 30” clear counter top with clear floor space for both kitchens. Sheet A-900, window #2 doesn’t comply with emergency egress. Detail 8 / S-1.0, doesn’t provide fire rated integrity. Detail 7/S-1.0 and 9/ S-1.0 doesn’t comply with I-Hr fire rated detail.