HomeMy WebLinkAbout328819_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101123573 PROJECT ADDRESS: 623 E Twentieth St PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 5/1/2025 INITIAL REVIEW 5/21/2025 EXPIRATION 10/28/2025 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Ray Estrada 3. TEL: (714)345-8704 FAX: VALUATION: $2,000.00 EMAIL: rayallen@kingroofingca.com FLOOD ZONE: X-06059C0163J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment. The applicant shall obtain clearances/approvals for the following after obtaining approval from Building and Safety Division, prior to building permit issuance (CHECKED BOXES REQUIRED ONLY): ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☐Public Works Agency approval (647-5039). ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☒School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. Applicant must pick up red marked sets from city prior to resubmittal and return marked up set with resubmittal.DrawingsSheet 1 of 5Justify 24” minimum clear height is provided with 48” high single hung window in bedroom including window rail consideration. Increase height as needed.Provide added sheet to Sheet Index, revise Sheet Index as needed.Provide revised Title 24 conformance for new total square foot addition.Sheet 2 of 5(N) Foundation Plan is illegible, please fix linework.Footing and slab on grade hatch is hard to distinguish, please make more clear.Sheet 3 of 5Detail 4 – Footing rebar does not match plans, revise to match.Detail 6 – ICC ESR # is not correct, revise as needed.Detail 9 – Specify shear transfer from existing roof rafter and new roof rafter to drop beam. Drop beam looks to be a drag to new shearwall at Grid B, provide full lateral load path. Sheet 3 of 5 (2)Revise sheet label to 4 of 5.Sheet Sheet 4 of 5Revise sheet label to 5 of 5.(End of Comment)