Loading...
HomeMy WebLinkAbout325100_3_Corrections.docxSPC PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101122336 PROJECT ADDRESS: 2350 W Fifth St PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: N/A OCCUPANCY CLASSIFICATION(S): N/A PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/30/2025 INITIAL REVIEW 2/20/2025 EXPIRATION 7/29/2025 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Michael C. Cardoso 3. TEL: (714)926-6250 FAX: VALUATION:$15,000.00 EMAIL: cardosoconsultingcc@gmail.com FLOOD ZONE:X-06059C0257J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process.PLAN CHECK COMMENTSOn the proposed site plan, please identify zero curb area (with dimensions) between vehicular parking, driveway and new walkways.Show on the site plan. Walks that cross or adjoin a route provided for vehicular traffic, such as in a street, driveway, or parking facility, shall be separated by detectable warnings, curbs, railings or other elements between the pedestrian areas and vehicular areas. §202, §11B-247.1.2.5, §11B-705.1.2.5Show on the site plan. Detectable warnings provided to separate walks that cross or adjoin a route provided for vehicular traffic, such as in a street, driveway, or parking facility, shall be 36 inches in width and continuous at the boundary between the pedestrian areas and vehicular areas. §202, §11B-247.1.2.5, §11B-705.1.2.5PC2: Missing detectable warnings along the path of travel at the zero curb area. See redline on sheet A2.2.Provide detectable warning details showing compliance with Section 11B-705.1.1.3.1.Show compliance. Detectable warning surfaces shall be yellow and approximate FS 33538 of Federal Standard 595C. §11B-705.1.1.3.1Access aisles shall be marked with a blue painted borderline around their perimeter. Please revise site plan and detail 1, 2 /AC1.1 to add missing borderlines.PC2: Missing blue painted borderlines at the access aisle. See redline on sheet A2.2 and AC1.1.END OF COMMENTS