HomeMy WebLinkAbout329309_2_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101123721
PROJECT ADDRESS:
218 W Fourth St Unit# A
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830
EMAIL:
aso@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B, SPK
OCCUPANCY CLASSIFICATION(S):
B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
5/15/2025
INITIAL REVIEW
5/16/2025
EXPIRATION
11/11/2025
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Gani Dino
3.
TEL:
(323)217-3558
FAX:
VALUATION: $40,000.00
EMAIL:
ganiedino@yahoo.com
FLOOD ZONE: X-06059C0276J
GENERAL REQUIREMENTS
Before approval for code compliance or issuance of a building permit, the plans and specification for this construction require the information, revisions and corrections indicated below. The approval of plans and specifications does not permit the violation of any section of the building code, or other ordinance or state law.
This plan check will expire 180 days from the submittal date unless a written extension request is submitted and approved. The request must demonstrate justifiable cause. The Building Official may grant a one-time extension of up to 180 additional days. No further extensions will be granted beyond 360 days from the original submittal date.
This review does not include Mechanical, Electrical, and Plumbing (MEP).
Additional plan check fee will be required after the third review on hourly basis.
Obtain any applicable approval from the following agencies prior to permit issuance:
Planning Division – The plans approved by the Building Division must include the Planning approval stamp. Building staff will notify the Planning Division for approval. For approval status, contact the Planning Division at (714) 647-5804 or visit the Planning Division counters.
Public Works Agency (PWA) – Obtain PWA clearance if any of the following applies: project valuation exceeds $30,000, project has added plumbing fixtures, added bedrooms, or project exceeds 500 square foot in new construction (not renovation). After the Building Division approves your project, visit the Building Division counters and request a copy of the approved plan. Bring the approved plan to the PWA counters for approval. After PWA approves your project, return the approved plan to the Building Division counters.
Police Department (PD) – The plans approved by the Building Division must include the PD approval stamp. After the Building Division approves your project, Building staff will notify PD for approval. For approval status, contact the PD at (714) 647-5840 or email PolicePlanCheck@santa-ana.org.
Orange County Fire Authority (OCFA) - Submit plans to OCFA immediately if you answer “Yes” to any part of questions 1 through 10 on the plan submittal criteria. Bring an OCFA approved plan to the Building Division counters for permit issuance. Contact OCFA for approval status.
County of Orange, Health Care Agency, Environmental Health (OC Health) – Submit plans to OC Health if the business involves food service. Contact OC Health for submittal requirements. If OC Health approval is required, bring an OC Health approved plan to the Building Division counters for permit issuance.
School District – After the Building Division approves your project, Building staff will send a School Fee Form to your school district if school fee applies to your project. Applicant shall pay the school fee and bring the signed Certificate of Compliance form to the Building Division counters for permit issuance.
Cal/OSHA – Check the Cal/OSHA permit requirements here.
INSTRUCTIONS
Plans Pickup
The original plans and calculations are available for pickup at the building division counters on a walk-in basis. No appointment is necessary. Please check the holiday closure schedule before planning your visit.
Plan Check Corrections
Address all items noted on this plan check report, either directly on this list or in a separate document.
Address each correction thoroughly and provide a complete response. Do not leave any blanks. Indicate the sheet number, detail number, or note number where you make each correction. If a plan check correction does not apply to your project, provide an explanation in your response.
If you have any questions, contact Senior Plan Check Engineer Anson So at 714-647-5830 or by email at aso@santa-ana.org.
Resubmittal
Resubmit the red-marked plans and calculations, if applicable.
Resubmit your responses to corrections.
Resubmit two corrected sets of construction documents, including plans, structural calculations, energy documents, soils report, and any other related documents. For new construction or additions, provide an additional corrected set.
Resubmit all construction documents using one of the following options:
Resubmittal Bin:Complete the Plan Check Re-Submittal Form and include it with your resubmittal. The resubmittal bin is located at the building division lobby. Check the holiday closure schedule before your visit.
Walk-ins:Resubmittals are accepted on a first-come, first-served basis during daily walk-in hours. However, scheduled appointments take priority over walk-ins.
Appointment:Call the building division at 714-647-5800 to schedule a resubmittal appointment.PLAN REVIEW COMMENTSSheet T-1A tenant space used for assembly purposes with an occupant load of less than 50 persons shall be classified as a Group B occupancy.Revise the occupancy group from A2 to B throughout the plans, including the building data, site plan, and occupancy table. (303.1.1)Revise the occupant load calculations for the seating area. For non-fixed seating, calculate the occupant load by dividing the net floor area by a load factor of 15 (Table 1004.5).Sheet A-2.0Revise the occupancy group to B in Unit 218A.
Show exit signage at Door #3 (located at the back of the kitchen) and Door #2 (exterior exit).The common path of egress travel exceeds 100 feet; therefore, two exits are required for both Unit 218 and Unit 218A. Add the following note on the plan:Required number of exits: 2Provided number of exits: 2Clearly show the following note on the plan:”See separate building permit 101123724 for demising wall construction and restroom alterations.”Accessible seating is provided in the main seating area; however, the bar counter area must also include accessible seating.Per CBC Section 11B-226.2, accessible dining surfaces must be dispersed throughout the space for each type of seating provided.The lower portion of the bar counter meets the required height range of 28 inches minimum to 34 inches maximum (per CBC Section 11B-902.3), but it does not provide the required knee and toe clearance as specified in CBC Section 11B-306.To comply fully with CBC Section 11B-902, provide:Clear floor space positioned for a forward approach.Knee clearance at least 27 inches high, 30 inches wide, and 19 inches deep.Toe clearance at least 9 inches high, 17 inches deep, and aligned with knee clearance.Accessible seating that is integrated with other seating areas.Revise the design accordingly to provide full accessibility at the bar counter.End of Comments