HomeMy WebLinkAbout329872_1_Corrections.docxPLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101123886 PROJECT ADDRESS: 3615 S Aspen Village Way PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/4/2025 INITIAL REVIEW 7/8/2025 EXPIRATION 12/1/2025 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Tom Flitsch 3. TEL: (805)338-2883 FAX: VALUATION: $20,000.00 EMAIL: tom.flitsch@tjfarchitects.com FLOOD ZONE: X-06059C0259J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). Plan shall be legible. Please increase font size and upsize the scale to the next larger scale. Provide detail for stairway riser and tread. Show dimensions. (1011.5.2) Outdoor stairways and deck shall be designed so that water will not accumulate on walking surfaces. Provide barrier under the stairway. A barrier shall be provided where the vertical clearance above a circulation path is less than 80 inches high above the finished floor. The leading edge of such a barrier shall be located 27 inches maximum above the finished floor. Provide/show handrails on both sides of stairway. Provide detail to show handrail height (34”-38”); guardrail shall be 42”, and handrail extension at top and bottom of each stairway flight. Provide structural framing plan for the deck and stairway way repair. Show existing and new deck framing, including deck joists and posts New plywood-decking specification (thickness and nailing). Show existing and new stringers Provide structural details for connection and attachment. Structural calculation: Please check existing stairway, deck frame and its support for 100 psf live load. Provide lateral support for the existing stairway and deck. (End of Comment)