HomeMy WebLinkAbout327101_3_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101122971 PROJECT ADDRESS: 2210 W Bobby Ln PLAN CHECK ENGINEER: Huang, GaryTEL:714 647-5862 EMAIL: Ghuang@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/20/2025 INITIAL REVIEW 5/1/2025 EXPIRATION 9/16/2025 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Isaias Herrera 3. TEL: (323)975-5049 FAX: VALUATION: $95,000.00 EMAIL: isaias@bluecapco.com FLOOD ZONE: X-06059C0144J GUIDELINES: Comments contained within this report reflect only those of the Building and Safety Division. Additional comments or corrective action may be required by other Departments and/or outside Agencies This Plan Review Report and all subsequent code references are based upon the most recent version(s) of the 2022 California Building Codes (CBC, CRC, CFC, CEC, CPC, CMC, CGBSC, and CEES) The approval of plans and any supporting documents does not permit the violation of any section of the adopted building codes or other pertinent local ordinances, or state and federal laws All listed plan review comments must be adequately addressed before a building permit can be issued Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used. Applicant shall obtain clearance/approvals from following departments after obtaining approval from Building and Safety Division, prior to building permit issuance ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☒Police Department approval on the corrected/final set of drawings (647-5840). ☒Public Works Agency approval (647-5039). ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☒School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039). Applicant must pick up red marked sheet from the City prior to resubmittal and return the marked up set with resubmittal PLAN REVIEW COMMENTS: Sheet GN-1 Note on plan: Mechanical, electrical and plumbing are not part of this plan review and approval. MEP are subject to building field inspection. Sheet Index: provide missing sheet S3 for review or update sheet index Sheet A-3 Provide drawing scale. (E) Bedroom 4: provide wall dimension for the skew wall. See red-marked comment set Attic access and Ventilations – Show on the plans - attic vent locations, type and size (area = 1/150 of the attic space). Provide an attic cross ventilation summary; on the plans indicate the total area required versus provided. (R806.1) (N) Living room to exterior: on the plan, provide a landing or floor on each side of each exterior door. Landing shall have width of not less than the door served and a minimum of 36” measured in the direction of travel. Exterior wall covering – Provide detail to show exterior wall covering with water-resistive barrier in accordance with Section R703.2. Sheet S2 Clarify if 2x8 ridge (over new living room) is a ridge beam or a ridge board; If it is a ridge board – provide collar tie size, spacing, location (in height) and connection If it is a ridge beam – provide beam supporting framing detail Please see marked-up plans for additional requirement/comments. [Comment not complete – detail 18/SD1 is not consistent with information shown on the plan. Detail shown there are 2x ceiling joist connecting to 6x12 ceiling beam with diagonal bracing connect to the ceiling joist. However, there are ceiling joist call-out on plan. EOR to provide ceiling joist size, span or coordinate/revise detail] (End of Comment)