HomeMy WebLinkAbout330191_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101124006 PROJECT ADDRESS: 2208 N Flower St PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/13/2025 INITIAL REVIEW 7/23/2025 EXPIRATION 12/10/2025 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Barsam Design LLC 3. TEL: (818)427-6723 FAX: VALUATION: $150,000.00 EMAIL: info@barsamdesign.com FLOOD ZONE: X-06059C0144J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment. The applicant shall obtain clearances/approvals for the following after obtaining approval from Building and Safety Division, prior to building permit issuance (CHECKED BOXES REQUIRED ONLY): ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☒Public Works Agency approval (647-5039). ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. Applicant must pick up red marked sets from city prior to resubmittal and return marked up set with resubmittal.DrawingsSheet A02Green Building Standards Code shall be updated to July 2024 Supplemental version.Green Building Standards Code checklist shall be completed prior to approval. Sheet A04Roof Ventilation – number of roof vents shown on plan shall match calculations for clarity. Verify ventilation provided, gable vents are shown on elevations. Sheet A06Ensure handwritten items are revised in resubmitted set (family room to Bedroom)Specify minimum airflow requirement for new kitchen range hood per 2022 California Energy Code Section 150.0(o) and Table 150.0-G.Sheet A07Revised room labels to match sheet A06.Provide smoke alarm and carbon monoxide alarm directly outside vicinity of bedrooms. One of each alarm shall be provided on each end of hallway to cover bedrooms on opposite ends.Sheet A08Doors P5 and P6, and Window N4 shall be tempered.CalculationsCalculation package shall be fully bound prior to approval.Page 54 of 140 – Beam labels not found on plans or in calculation package indicating designed member location. Please verify/provide locations for review.(End of Comment)