HomeMy WebLinkAbout329842_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101123877 PROJECT ADDRESS: 1008 E Chestnut Ave PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B OCCUPANCY CLASSIFICATION(S): M PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/4/2025 INITIAL REVIEW 6/14/2025 EXPIRATION 12/1/2025 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Arlen Giragosian 3. TEL: (818)426-2669 FAX: VALUATION: $10,000.00 EMAIL: arleng78@gmail.com FLOOD ZONE: X-06059C0276J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment.Please return marked up set of drawings with corrections. The applicant shall obtain clearances/approvals for the following after obtaining approval from Building and Safety Division, prior to building permit issuance (CHECKED BOXES REQUIRED ONLY): ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☐Public Works Agency approval (647-5039). ☒Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. Applicant must pick up red marked sets from city prior to resubmittal and return marked up set with resubmittal.DocumentationAccessible path of travel shall be provided for alteration, for construction cost less than or equal to valuation threshold, 20 percent of construction cost of alterations shall be used to upgrade accessible path of travel. [2022 CBC Ch11B-202]DrawingsSheet A000Scope of work shall specify legalizing installed storage racks to match application. Provide the following design data on the first sheet (R106.1.1) ☐Sheet Index ☒Occupancy groups ☒Type of construction ☒Automatic Fire Sprinkler (YES or NO) ☒Number of stories. ☐Flood Zone: X ☐Flood Zone: A ☐Flood Zone: AE ☒Floor area per occupancy group, including the existing structure(s) ☐Construction shall comply with the 2022 CRC, CBC, CPC, CMC, CEC, California Green Building Code, and California Energy Efficiency Standards Code editions.Sheet A101Google view not acceptable on Site Plan. Site Plan shall be drawn without any background.Sheet A102Provide dimension between shelf along west wall and aisles of shelves.Sheet S-1.0Coordinate with arch for shelving on west wall.Coordinate with arch for shelf width. Arch sheets specify 3’-6” shelf. Verify if shelves are pre-manufactured. Provide specs for pre-manufactured shelf, e;seCalculationsAdd weight for any storage weight capacity to calculation loading as needed.(End of Comment)