HomeMy WebLinkAbout331258_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101124290
PROJECT ADDRESS:
1415 S Poplar St
PLAN CHECK ENGINEER:
Lo, JonathanTEL:714
647-5822
EMAIL:
Jlo@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3, U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
7/10/2025
INITIAL REVIEW
8/8/2025
EXPIRATION
1/6/2026
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Luis Camacho
3.
TEL:
(714)552-4195
FAX:
VALUATION: $75,000.00
EMAIL:
FLOOD ZONE: X-06059C0257J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment.
The applicant shall obtain clearances/approvals for the following after obtaining approval from Building and Safety Division, prior to building permit issuance (CHECKED BOXES REQUIRED ONLY):
☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process.
☒Public Works Agency approval (647-5039).
☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700).
☐Police Department approval on the corrected/final set of drawings (647-5840).
☒School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work.
☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. Applicant must pick up red marked sets from city prior to resubmittal and return marked up set with resubmittal.DrawingsSheet A-1Ensure all handwritten items done by applicant on submittal set are incorporated in resubmitted drawing set. (e.g. Existing unpermitted patio demolish note)Sheet A-4Gable vent is noted to not be provided in fire rated detail 4/A-4, however, gable vents are provided per ventilation calculation along wall requiring fire rated projection. Please verify and revise as needed.Sheet T-24Title 24 compliance shall be updated to 2022 code. Sheet S-1Verify gridlines, there are two Grid B’s.Underfloor ventilation – Verify any existing crawlspace vent that is covered by new addition is replaced. New calculated vents for new square footage might not be enough to replace for new total square footage if existing vents were covered. Provide HDU2 at each side of interior shearwall along Grid B. Justify cut/taper amount at ends of flush beams specified on framing plans. Amount of cut shall meet code allowance or be engineered.CalculationsProvide deflection check for new flush beams.(End of Comment)