HomeMy WebLinkAbout331703_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101124418
PROJECT ADDRESS:
2017 W San Lorenzo Ave
PLAN CHECK ENGINEER:
Huang, GaryTEL:714
647-5862
EMAIL:
Ghuang@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
7/21/2025
INITIAL REVIEW
7/25/2025
EXPIRATION
1/17/2026
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Youssef Malek
3.
TEL:
(310)802-9570
FAX:
VALUATION: $15,000.00
EMAIL:
Y.Malek@ymdexperts.com
FLOOD ZONE: X-06059C0259J
GUIDELINES:
Comments contained within this report reflect only those of the Building and Safety Division. Additional comments or corrective action may be required by other Departments and/or outside Agencies
This Plan Review Report and all subsequent code references are based upon the most recent version(s) of the 2022 California Building Codes (CBC, CRC, CFC, CEC, CPC, CMC, CGBSC, and CEES)
The approval of plans and any supporting documents does not permit the violation of any section of the adopted building codes or other pertinent local ordinances, or state and federal laws
All listed plan review comments must be adequately addressed before a building permit can be issued
Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.
Applicant shall obtain clearance/approvals from following departments after obtaining approval from Building and Safety Division, prior to building permit issuance
☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process.
☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700).
☐Police Department approval on the corrected/final set of drawings (647-5840).
☐Public Works Agency approval (647-5039).
☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work.
☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).
Applicant must pick up red marked sheet from the City prior to resubmittal and return the marked up set with resubmittal
PLAN REVIEW COMMENTS:
Cover sheet:
Note on plan: Mechanical, electrical and plumbing are not part of this plan review and approval. MEP are subject to building field inspection.
Coordinate sheet index. Missing sheet A-9. Provide sheet A-9 for review
Update scope of work, see comment on sheet A-2
Sheet A-2
Per California building code, every sleeping room required one operable emergency escape and rescue opening. Provide emergency escape opening comply with CRC R310.2.2, and R310.2.3. Indicate the dimension/location on plan and elevation. Where new opening interrupted the existing shear wall, EOR to provide calculation justification that remained length is adequate. Show on plan the location of shear wall and holdown where required. Further review is reqired.
Sheet S-1
EOR to provide maximum lumber notch/cut detail for new roof joist
Provide weep screed detail
Provide double top plate splice detail
Detail 2
Provide connection to tie (N) footing to (E) footing
Provide shear transfer from roof joist blocking to double top plate
Prior to submit the hard-copy drawings for approval and permit issuance. It is at applicant’s discretion, as an option, to submit a full-set electronic drawing (in pdf format) for a courtesy review. Please include the original red-marked comment drawing set, red-marked calculation, and all supporting document (revised calculation, etc.) for an expedite review.
Red marked comment set is available to pick-up at the City Hall.(End of Comment)